Connection and installation manual

Swing gate control unit ST 61

 

V 3.0.001

Safety Sensor

Summary of Contents for 12111670

Page 1: ...Connection and installation manual Swing gate control unit ST 61 V 3 0 001 Safety Sensor ...

Page 2: ...ion of the manual replaces all earlier publications of the same Content General warning and safety notes 3 1 General features control board overview technical data 4 2 Terminal assignment connection notes 5 3 Adjustments overview 6 7 4 Connections and adjustments 8 Buttons switches 8 9 Safety 10 13 Left leaf 16 Right leaf 16 Operating mode 16 17 Light Lamps 18 Peripherals 19 21 Diagnosis 22 5 Conn...

Page 3: ... purpose for which it has been exclusively designed and which is described in these installation and operating instructions The TOUSEK Ges m b H rejects any liability if the product is used in any way not fully conforming to its original purpose as stated herein Children have to be instructed that the gate facility as well as the belonging parts may not be used improperly e g for playing Furthermo...

Page 4: ...TSI connection optional tousek connect tousek service Interface E System connector for optional module motor lock or electric lock magnet page 20 VE 230V a c for electric lock magnet module B system connector FE slot for optional radio receiver page 23 ZM slot for optional module status display page 19 T transformer F1 fuse 6 3A F Control board overview Technical data Swing gate control unit ST 61...

Page 5: ...ver 30 31 32 30 33 34 50 52 53 20 21 22 23 24 25 26 27 0 1 2 10 11 41 42 43 44 45 46 48 80 81 82 83 Warning Before taking off the control cover the main switch must be turned off The inside of the control unit is under tension when power supplied In order to avoid electrical strokes the safety regula tions have to be respected The device may only be connected by qualified per sonnel specialised st...

Page 6: ...r and choose the language for the menuas and press ENTER Note The language setting can be changed any time by pressing the ESC button for 5s Before you can start programming you have to select the operator SWING X or SPIN 250 The text display informs you on the operating modes selected menus and adjustment of several parameters The programming of the control is done through four but tons ENTER and...

Page 7: ...0 100 70 soft stop time 0 25s 5s soft start not active active only with SWING X operating mode page 16 17 impulse logic stop start of pause time impulse suppression when opening pause time extension G operating mode impulse mode automatic 1 255s increment 1 partial opening 25 100 100 automatic mode complete partial opening only complete opening only partial opening pause time logic no influence pe...

Page 8: ...tion OPEN CLOSE OPEN we strongly suggest the installation of a photocell OPEN Only opening commands are accepted by the impulse switch closing the gate with the impulse switch is not possible DEAD MAN The motor opens as long as the impulse switch is pressed hold closing the gate with the impulse switch is not possible As soon as the switch is released the motor stops If hold to run operating mode ...

Page 9: ...s actuated again during this movement the motor stops With the next impulse the motor moves in opposite direction of the last gate movement OPEN CLOSE OPEN successive impulses Acommand of the pedestrian button makes the according gate wing open close If the button is actuated again during this movement the travel direction is reversed In this operation mode it is not possible to stop the motor wit...

Page 10: ...ounting notes SYNC function IMPORTANT When using two pairs of photocells please do not install both photocell transmitters receivers on the same side to eleminate interference between both Exception photocells with SYNC function allow the installation of both photocell transmitters receivers on the same side without causing interference to each other Self monitoring of photocells The control unit ...

Page 11: ...e transmitter receiver transmitter receiver OUTSIDE INSIDE transmitter receiver with active SYNC function Photocells connection examples Important Jumper J of transmitter and receiver has to be adjusted in the same way Outer photocell Tousek LS 26 as safety device Outer reflective photocell Tousek RLS 620 as safety device N O COM N C N O COM N C N O COM N C 48 45 44 43 42 41 46 12 24V J 12 24V NC ...

Page 12: ...safety sensing edges is made in menu Safety main closing edge 1 term 50 52 and Safety main closing edge 2 term 50 53 If in the menu item operating logic closing edge page 17 one of the modes left right or inside outside is selected this results in the wiring of the safety contact edges to make with each other and the connection to the control terminals Safety sensing edges in mode left right that ...

Page 13: ...given stop after release open an interruption of the photocell beam during opening or closing makes the motor stop as long as the photocell stays interrupted After release of the photocell the gate opens In automatic mode the gate closes as soon as the pause time has run out in impulse operation another closing command has to be given PHC pause time Safety no influence of photocell the photocell d...

Page 14: ...ttention Before carrying out any connection works the power supply of the gate facility has to be turned off Operators power supply and sensor cables as well as the capacitors must be connected to the ST 61 control unit acoording to the installation manual The sensor signal defines the performance response when hitting an obstacle or when reaching a gate end position adjustment of sensor sensibili...

Page 15: ... right 2 1 3 yellow green black blue brown 3 2 1 S M Motor line M to control unit Sensor line S to control unit to control unit SPIN 250 terminals Steuerungsklemmen number colour left operator to terminal right operator to terminal M power supply 4 brown 20 24 5 blue or grey 21 25 6 black 22 26 green yellow 23 27 S Sensor 1 red 65 65 2 blue 66 67 3 black 68 68 Connection SPIN 250 Connection SWING ...

Page 16: ... as soon as the pause time has run out the gate closes automatically impulse suppression when opening commands which are emitted during the opening movement are suppressed Commands during closing are accepted pause time extension an impulse in automatic operation restarts the pause time If this menu point is chosen the impulse suppression during opening is active at the same time Operating mode Co...

Page 17: ... and the control unit goes back to automatic mode With this function e g the entrance to a company site can remain open during the day 1st impulseingateopenposition andclosedintheevening 2ndimpulse Thecontrolboardswitchesbacktoautomaticmode autom opening and closing of gate If the gate is in partial open position and permanent open in automatic mode is selected so it is possible to adjust permanen...

Page 18: ... or when the gate stops it is illuminated During the closing movement it flashes rapidly If the gate is closed the pilot lamp expires illuminates in open position Pilot lamp is illuminated as soon as the gate has reached end position open Before taking off the housing cover the main switch has to be turned off Follow safety instructions page 5 Warning Important Notes regarding connection of a flas...

Page 19: ...ule optional turn off power supply before installing the additional module Depending on which device e g a courtyard Control lamp is chosen or evaluation of gate status should be effected the corresponding module Z has to be plugged to the according slot plug ZM of control board Additionally the corresponding value has to be selected in menu point Additional module Additional module Courtyard lamp...

Page 20: ... and closed position of the gate the electric lock only in closed position P1 E VE 72 73 7475 V electric lock 12 or 24Vd c magnet 24Vd c R fix 24V The series resistor R is for tousek magnets GD 50 and GD 70 WARNING Before taking off the housing cover the main switch has to be turned off Follow safety instructions page 5 optional dropbolt module In order to connect the dropbolt SAFELOCK to the cont...

Page 21: ... 2 dropbolts wire with terminal blocks X Y on the other hand wire it with the dropbolt via connection cable 4 x 0 752 motor connection and limit switch Strictly note the numbering 1 4 of the connection cable s wires for a proper connection Carry out the 230V a c power supply connection on terminal block V and the earthing connection on the earthing screw SAFELOCK control unit with 2 motor prints s...

Page 22: ...setting Diagnosis NO no reset to factory setting YES reset to factory setting Software version Diagnosis shows the software version and the operator type on the text display Serial number Diagnosis shows the serial number on the text display All inputs OK e g Diagnosis Connections and adjustments The mechanical stops have to be placed so that possibly existing safety contact edges can not be trigg...

Page 23: ...For programming of receiver please see manual for radio receiver Disconnect the power supply Plug in the receiver printed circuit board E RS433 868 STN1 1 channel or RS433 868 STN2 2 channels into the corresponding slot FE as shown in the picture For range extension an external antenna FK433 or FK868 can be connected 5 Connecting the receiver Swing gate control ST 61 ...

Page 24: ...ns of gate is made 6 Putting into operation Swing gate control unit ST 61 LANGUAGE SELECTION Can be selected during initial operation hence after reset to factory settings Can be also chosen by pressing the ESC button for 5s from any position in menu BASIC SETTING For setting the most important adjustments for initial operation of motor Can be selected during initial operation hence when restoring...

Page 25: ...tive change YES adopt 5 left term 50 52 6 mainsafety edge1 mainsafety edge1 active mainsafety edge1 not active change YES adopt 6 left term 50 52 mainsafety edge1 radio edge TX 6 adopt left term 50 52 8 7 mainsafety edge2 mainsafety edge2 active mainsafety edge2 not active change YES adopt 7 mainsafety edge2 radio edge TX 7 adopt right term 50 53 right term 50 53 right term 50 53 ...

Page 26: ...ft ON change YES motor left OFF adopt 7 8 8 delay left leaf delay left leaf opening delay change YES delay left leaf closing delay adopt 9 9 left operator motor right motor right ON change YES motor right OFF adopt delay right leaf delay right leaf closing delay change YES delay right leaf opening delay adopt right operator right operator 2s 10 11 11 12 12 13 ...

Page 27: ...tion being detected Close position being detected Ready delay time right delay time right 2s delay time right 10s change YES adopt 14 time 0 25s 15 e g 10s 2s 13 13 14 left motor right motor INSIDE Important The gate installation 1 or with 2 leaves has to reflect in the settings of the main menu Factory setting Operation of swing gate with 2 gate leaves the left and right operator are turned on in...

Page 28: ...itioning and functions of photocells AR system actuated check force and sensor adjustment safety sensing edge 1 or 2 actuated adjustment of safety sensing edges wrong remove obstacle or function control via status display no reaction of radio receiver radio receiver plugged into wrong connector check proper installation see 5 connection of radio receiver no wrong connected antenna check antenna co...

Page 29: ... 176 170 265 9 4 210 310 125 8 Dimensioned drawing housing IP54 Swing gate control unit ST 61 dimensions in mm Mounting dimensions back side We reserve the right to change dimensions and technical specifications without prior notice ...

Page 30: ... 30 tousek E_ST61_07 06 06 2019 Notes ...

Page 31: ......

Page 32: ...ic Gliwicka 67 Tel 48 32 738 53 65 Fax 48 32 738 53 66 info tousek pl Tousek s r o Czech Republic CZ 252 61 Jeneč u Prahy Průmyslová 499 Tel 420 777 751 730 info tousek cz We reserve the right to change dimensions and or technical specifications with out prior notice Claims resulting from misprints or errors cannot be accepted tousek PRODUCTS sliding gate operators cantilever systems swing gate op...