WX9 ASD Installation and Operation Manual
173
Send Waiting Time (TTL)
Program
Communications
Communication Settings
This parameter sets the
TTL
response delay time.
Note:
Changes made to this parameter require that the power be cycled
(off then on) for the changes to take effect.
Direct Access Number — F805
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 2.00
Units — Seconds
ASD to ASD Communication (TTL)
Program
Communications
Communication Settings
In a master/follower configuration, this setting determines the output parameter
of the master ASD that will be used to control the applicable follower ASDs.
Note:
Select
No Follower
if
ASD to ASD Communication (RS232/
RS485)
is configured as a
Master Output
controller.
Otherwise, an
EOI
failure will result.
Note:
Changes made to this parameter require that the power be cycled
(off then on) for the changes to take effect.
Settings:
0 — Normal (No Follower)
1 — Frequency Command
2 — Output Command Frequency
3 — Torque Command
4 — Output Torque Command
Direct Access Number — F806
Parameter Type —
Selection List
Factory Default —
Normal (No
Follower)
Changeable During Run —
Yes
Frequency Point Selection
Program
Communications
Communication Adjustments
This parameter selects the communications reference for scaling.
See
for additional information on this setting.
Note:
Scaling the communications signal is not required for all
applications.
Note:
Changes made to this parameter require that the power be cycled
(off then on) for the changes to take effect.
Settings:
0 — Disabled
1 — Common Serial (TTL)
2 — RS232/RS485
3 — Communication Option
Direct Access Number — F810
Parameter Type —
Selection List
Factory Default —
Disabled
Changeable During Run —
Yes
Summary of Contents for WX9 ASD
Page 2: ......
Page 3: ...DN 68940 000 March 2014 WX9 ASD Installation Operation Manual ...
Page 4: ......
Page 12: ...iv WX9 ASD Installation and Operation Manual ...
Page 225: ......