WX9 ASD Installation and Operation Manual
155
Deceleration Time 3
Program
Special
Acc/Dec (1 - 4) Settings
This parameter specifies the time for the drive to go from the
Maximum
Frequency
to 0.0 Hz for the
Deceleration (Dec) 3 Profile
.
The
Acceleration/Deceleration (Acc/Dec)
pattern may be set using
.
The minimum
Acceleration/Deceleration (Acc/Dec)
time may be set using
Note:
A deceleration time that is shorter than the load will allow may
cause nuisance tripping and mechanical stress to loads.
Automatic Acceleration/Deceleration
,
Stall
, and
Ridethrough
settings
may lengthen the deceleration time.
Direct Access Number — F511
Parameter Type —
Numerical
Factory Default —
(ASD-Dependent)
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 6000.00
Units — Seconds
Acceleration/Deceleration Pattern 3
Program
Special
Acc/Dec (1 - 4) Settings
This parameter enables a user-selected preprogrammed output profile that
controls the acceleration and deceleration pattern for the
Acceleration/
Deceleration (Acc/Dec) 3
parameter.
Settings:
0 — Linear
1 — S-Pattern 1
2 — S-Pattern 2
Direct Access Number — F512
Parameter Type —
Selection List
Factory Default —
Linear
Changeable During Run —
Yes
Acceleration/Deceleration Switching Frequency 2
Program
Special
Acc/Dec Special
This parameter sets the frequency at which the acceleration control is switched
from the
Acceleration (Acc) 2
Profile
to the
Acceleration (Acc) 3
Profile
during a multiple-profile configuration.
Direct Access Number — F513
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — Maximum Freq. (
Units — Hz
Acceleration Time 4
Program
Special
Acc/Dec (1 - 4) Settings
This parameter specifies the time for the drive to go from 0.0 Hz to the
Maximum Frequency
for the
Acceleration (Acc) 4 Profile
. The
Acceleration/Deceleration (Acc/Dec)
pattern may be set using
minimum
Acc/Dec
time may be set using
.
Note:
An acceleration time that is shorter than the load will allow may
cause nuisance tripping and mechanical stress to loads.
Automatic Acceleration/Deceleration
,
Stall
, and
Ridethrough
settings
may lengthen the acceleration time.
Direct Access Number — F514
Parameter Type —
Numerical
Factory Default —
(ASD-Dependent)
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 6000.00
Units — Seconds