WX9 ASD Installation and Operation Manual
133
Number of PG Input Pulses
Program
Feedback
PG Settings
This parameter is used to set the end-of-travel range when using an encoder on
a motor-driven positioning system (e.g., hoist/crane, etc.).
Note:
The
PG Vector Feedback Board
option is required to use this
feature.
Direct Access Number — F367
Parameter Type —
Numerical
Factory Default —
500
Changeable During Run —
No
Minimum — 1
Maximum — 9999
Units — Pulse Count
Selection of Number of PG Input Phases
Program
Feedback
PG Settings
This parameter determines the type of information that is supplied by the phase
encoder.
Note:
The
PG Vector Feedback Board
option is required to use this
feature.
Settings:
1 — Single Phase
2 — Two Phase
Direct Access Number — F368
Parameter Type —
Selection List
Factory Default —
Two Phase
Changeable During Run —
No
PG Disconnection Detection
Program
Feedback
PG Settings
This parameter Enables/Disables the system’s monitoring of the PG connection
status when using encoders with line driver outputs.
Note:
The
PG Vector Feedback Board
option is required to use this
feature.
Settings:
0 — Disabled
1 — Enabled
Direct Access Number — F369
Parameter Type —
Selection List
Factory Default —
Disabled
Changeable During Run —
Yes
Electronic Gear Setting (pulses/rotations)
Program
Feedback
PG Settings
This parameter sets the number of pulses per revolution when using a shaft-
mounted encoder and the
PG
Option Board
for closed loop speed control.
Direct Access Number — F370
Parameter Type —
Numerical
Factory Default —
1000
Changeable During Run —
Yes
Minimum — 100
Maximum — 4000
Summary of Contents for WX9 ASD
Page 2: ......
Page 3: ...DN 68940 000 March 2014 WX9 ASD Installation Operation Manual ...
Page 4: ......
Page 12: ...iv WX9 ASD Installation and Operation Manual ...
Page 225: ......