2-22
T3400/T3400CT Maintenance Manual
Procedure 4
Diagnostic Test Program Execution Check
The HDD test program is stored on the T3400/T3400CT Diagnostics Disk. Perform all of the
HDD tests in the Hard Disk Drive Test. Refer to Chapter 3,
Tests and Diagnostics
, for more
information about the HDD test program.
If an error is detected during the HDD test, an error code and status will be displayed; per-
form Check 1. Error codes and status are listed in Table 2-4. If an error code is not
generated, the HDD is operating properly.
Table 2-4 Hard Disk Drive Error Code and Status
Code
Status
01h
Bad command
02h
Bad address mark
04h
Record not found
05h
HDC not reset
07h
Drive not initialized
08
HDC overrun (DRQ)
09h
DMA boundary error
0Ah
Bad sector error
0Bh
Bad track error
10h
ECC error
11h
ECC recover enable
20h
HDC error
40h
Seek error
80h
Time out error
AAh
Drive not ready
BBh
Undefined error
CCh
Write fault
E0h
Status error
EEh
Access time out error
FFh
Data compare error
Check 1
Replace the HDD unit following the instructions in Chapter 4,
Replacement
Procedures
. If the HDD is still not functioning properly, perform Check 2.
Check 2
Replace the flexible cable following the instructions in Chapter 4,
Replacement
Procedures
.
If the HDD is still not functioning properly, replace the system board.
Summary of Contents for T3400
Page 20: ...T3400 T3400CT Maintenance Manual 2 3 Figure 2 1 Troubleshooting Flowchart ...
Page 149: ...B 2 T3400 T3400CT B 2 System Board Back View Figure B 2 Board Layout Back ...
Page 151: ...B 4 T3400 T3400CT ...
Page 161: ...C 10 T3400C T3400CT ...
Page 162: ...T3400 T3400CT D 1 Appendix D USA Display Codes Table D 1 USA Display Codes ...
Page 163: ...D 2 T3400 T3400CT ...
Page 175: ...F 6 T3400 T3400CT ...
Page 179: ...H 2 T3400 T3400CT ...