3.22 Log Utilities
3 Tests and Diagnostics
3.22.2 Operations
1.
Select
5
and press
Enter
in the DIAGNOSTIC MENU, the error information is
displayed in the following format:
XXXXX ERRORS
CNT TS-NO PASS
STS ADDR
WD
RD HSTS [ERROR STATUS NAME]
001 FDD 02 0000 103 00001
00 00 0000 FDD-WRITE PROTECTED
001 FDD
01
0000
180
00001 00
00 0000 FDD-TIME OUT ERROR
Error count
Pass count
Error status
Address
Subtest number
Test name
Error status name
Read data
Write data
HDC status
[[1:Next,2:Prev,3:Exit,4:Clear,5:Print,6:FD Log Read,7:FD Log Write]]
2.
The error information displayed on the screen can be manipulated by the following
number keys:
The
1
key scrolls the display to the next page.
The
2
key scrolls the display to the previous page.
The
3
key returns to the Diagnostic Menu.
The
4
key erases all error log information in RAM.
The
5
key outputs the error log information to a printer.
The
6
key reads the log information from a floppy disk.
The
7
key writes the log information to a floppy disk.
3.
In the case of “error retry OK”, a capital “R” will be placed at the beginning of the
error status. However, it is not added to the error count.
TECRA A8 /Satellite Pro A120 Maintenance Manual (960-573)
[CONFIDENTIAL]
3-49
Summary of Contents for Satellite Pro A120
Page 10: ...x CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Page 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 12: ...1 Hardware Overview 1 ii CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Page 45: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Page 129: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 241: ...Chapter 4 Replacement Procedures CONFIDENTIAL ...
Page 337: ... CONFIDENTIAL Appendices ...
Page 338: ...Appendices App ii CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Page 346: ...Appendices App x CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...