2 Troubleshooting Procedures
2.8 Display Troubleshooting
2.8 Display
Troubleshooting
This section describes how to determine if the computer’s display is functioning properly.
Start with Procedure 1 and continue with the other procedures as instructed.
Procedure 1: Diagnostic Test Program Execution Check
Procedure 2: Connector Check and Cable Check
Procedure 3: Replacement Check
Procedure 1
Diagnostic Test Program Execution Check
The Display Test program is stored on the computer’s Diagnostics disk. This program checks
the display controller on the system board. Insert the Diagnostics disk in the computer’s
floppy disk drive, turn on the computer and run the test. Refer to Chapter 3,
Tests and
Diagnostics
for details. If an error is detected, go to Procedure 2.
Procedure 2
Connector Check and Cable Check
Check 1
The LCD, FL, FL Inverter Board and System Board are connected by the HV
cable and LCD/FL cable as shown bellow. Check the connections. The
connectors may be disconnected or damaged. Disassemble the computer
following the steps described in Chapter 4,
Replacement Procedures
.
If the connection is loose, reconnect firmly and restart the computer. If there is still an error,
go to Procedure 3.
2-56
[CONFIDENTIAL]
TECRA A8 /Satellite Pro A120 Maintenance Manual (960-573)
Summary of Contents for Satellite Pro A120
Page 10: ...x CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Page 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 12: ...1 Hardware Overview 1 ii CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Page 45: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Page 129: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 241: ...Chapter 4 Replacement Procedures CONFIDENTIAL ...
Page 337: ... CONFIDENTIAL Appendices ...
Page 338: ...Appendices App ii CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Page 346: ...Appendices App x CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...