3.26 Wireless LAN Test Program (Atheros)
3 Tests and Diagnostics
TECRA A8 /Satellite Pro A120 Maintenance Manual (960-573)
[CONFIDENTIAL]
3-61
4)
The following message is displayed. Change the FD with “MB6x setup media 2” and
press
Enter
. The file copy from the FD to the RAM drive is started.
Please exchange FD for "MB6x setup media 2"
Press any Key to continue . . .
5)
When the file copy is completed, the following test menu is displayed. Press
d
and
Enter
. The Responder T&D is started.
************************************************************
* *
* Atheros MB6x DUT mode Maintenance T&D Menu *
* *
* d : DUT mode *
* *
* r : Responder mode *
* *
************************************************************
SELECT MODE No.(d or r) :
6)
The following test menu is displayed. Select the test number.
************************************************************
* Atheros MB6x DUT mode Maintenance T&D Menu *
* 1 : SKU check of Module *
* 2 : MAC Address Check *
* 3 : Communication test of 11a mode *
* 4 : Communication test of 11a mode(Main Antenna Only) *
* 5 : Communication test of 11b mode *
* 6 : Communication test of 11b mode(Main Antenna Only) *
* 7 : Communication test of 11g mode *
* 8 : Communication test of 11g mode(Main Antenna Only) *
* 9 : All the tests of module *
* (SKU & MAC Check,11a/b/g communication test) *
* A : All the tests of module(Main Antenna Only) *
* (SKU & MAC Check,11a/b/g communication test) *
************************************************************
SELECT TEST No.(1-A) :
3.26.3 Contents of the test and errors
1. SKU check of Module
The SKU (destination) of the Wireless LAN card installed is displayed. Visually check it.
*********************************************
* *
* Module : Atheros MB62HL (MoW) *
* G-code : G360001Q210 *
* *
*********************************************
Summary of Contents for Satellite Pro A120
Page 10: ...x CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Page 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 12: ...1 Hardware Overview 1 ii CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Page 45: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Page 129: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 241: ...Chapter 4 Replacement Procedures CONFIDENTIAL ...
Page 337: ... CONFIDENTIAL Appendices ...
Page 338: ...Appendices App ii CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Page 346: ...Appendices App x CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...