2 Troubleshooting Procedures
2.4 System Board Troubleshooting
2-40
[CONFIDENTIAL]
TECRA A8 /Satellite Pro A120 Maintenance Manual (960-573)
Table 2-4-2 Debug port (Boot mode) error status (7/9)
D port status
Inspection items
Details
Timer initialization start
EC initialization & Reading of battery information
(F10F)
Update of system BIOS (Update of EDID information
for LCD)
Waiting VGA power on
F110
Waiting for VGA chip initialization
completion, VGA BIOS
initialization
Waiting completion of display access
F111
Call VGA BIOS
F113
DISP_LOGO (Displaying logo)
Start of waiting logo display DPORT=F125 (not
used)
F114
SYS_MEM_CHECK
(Check of convention memory)(Boot)
F115
EXT_MEM_CHECK
(Check of exception in the protected mode)(Boot)
Exception check in the protected
mode
DPORT=F117h when error occurs
F116
INIT_SYS_MEM
Initialization of conventional memory (Reboot)
F118
CHK_DMA_PAGE
(Check of DMA Page Register) (Boot)
F119
CHECK_DMAC
(Initialization of DMAC) (Boot)
F11A
INIT_DMAC
(Initialization of DMA) (Boot)
F11B
CHECK_PRT
(Check of printer existence) (For models supporting
Printer port)
F11C
CHECK_SIO
(Check of SIO) (model supporting SIO)
F11D
Displaying the result of
DIAGNOSTIC
(When the DIAGNOSTIC mode is permitted)
Waiting for FDD initialization completion in Reboot
mode (model with built-in FDD)
Waiting for HDD initialization completion
Check of key input during IRT (waiting for KBC
initialization completion)
I/O LOCK process (model supporting I/O LOCK)
Initialization of ATA priority in Boot mode
Key input check during IRT (waiting here completion
of KBC initialization)
Input password (Waiting completion of HDD
initialization)
F11E
BOOT_PASSWORD (Check of
password)
I/O LOCK process (model supporting I/O LOCK)
Summary of Contents for Satellite Pro A120
Page 10: ...x CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Page 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 12: ...1 Hardware Overview 1 ii CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Page 45: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Page 129: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 241: ...Chapter 4 Replacement Procedures CONFIDENTIAL ...
Page 337: ... CONFIDENTIAL Appendices ...
Page 338: ...Appendices App ii CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Page 346: ...Appendices App x CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...