2 Troubleshooting Procedures
2.3 Power Supply Troubleshooting
2-10
[CONFIDENTIAL]
TECRA A8 /Satellite Pro A120 Maintenance Manual (960-573)
AC Adaptor
Error code
Meaning
10h
AC Adaptor output voltage is over 16.5V.
11h
CommonDock voltage is over 16.5V.
12h
Current from the DC power supply is over 7.00A.
13h
Current from the DC power supply is over 0.5A when there is no load.
14h
Correction value of 0[A] is out of designed value.
1st Battery
Error code
Meaning
22h
1st battery discharge current over 0.5A when there is no load.
23h
1st battery charge current is over 3.9A in charging.
24h
Correction value of 0[A] is out of designed value.
25h
1st battery charge current is over 0.3A in not charging.
2nd Battery
Error code
Meaning
32h
2nd battery discharge current is over 0.5A when there is no load.
33h
2nd battery charge current is over 3.9A in charging.
34h
Correction value of 0[A] is out of designed value.
35h
2nd battery charge current is over 0.3A in not charging.
S3V output
Error code
Meaning
40h
S3V voltage is 3.47V or less when the computer is powered on/off.
45h
S3V voltage is under 3.14V in normal conditions.
46h
S3V voltage is under 3.14V when the computer is booting up.
Summary of Contents for Satellite Pro A120
Page 10: ...x CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Page 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 12: ...1 Hardware Overview 1 ii CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Page 45: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Page 129: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 241: ...Chapter 4 Replacement Procedures CONFIDENTIAL ...
Page 337: ... CONFIDENTIAL Appendices ...
Page 338: ...Appendices App ii CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Page 346: ...Appendices App x CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...