– 64 –
Check
code
Outdoor
LED display
Check and troubleshooting
(Item without special mention Indicates part of outdoor unit.)
[F04]
[Discharge temp. sensor (TD) trouble]
Is connection of CN603 correct?
Is resistance value of TD sensor correct?
YES
NO
Correct connector.
Replace TD sensor
Replace Interface
P.C. board.
Replace Interface
P.C. board.
Replace Interface
P.C. board.
Replace Interface
P.C. board.
Replace Interface
P.C. board.
[F06]
[Heat exchanger temp. sensor (TE) trouble]
Is connection of CN601 correct?
Is resistance value of TE sensor correct?
YES
NO
Correct connector.
Replace TE sensor
[F07]
[Heat exchanger temp. sensor (TL) trouble]
Is connection of CN604 correct?
Is resistance value of TL sensor correct?
YES
NO
Correct connector.
Replace TL sensor
[F12]
[Suction temp. sensor (TS) trouble]
Is connection of CN600 correct?
Is resistance value of TS sensor correct?
YES
NO
Correct connector.
Replace TS sensor
[F08]
[Outside temp. sensor (TO) trouble]
Is connection of CN602 correct?
Is resistance value of TO sensor correct?
YES
NO
Correct connector.
Replace TO sensor
[F13]
[Heat sink temp. sensor (TH) trouble]
Replace compressor IPDU P.C. board.
* When replacing Compressor IPDU P.C.board,
replace the fuse.