– 57 –
(A)
(B)
(C)
(D)
1 Installation plate
Insert the cushion between
the indoor unit and wall, and
tilt the indoor unit for better
installation work.
Make sure the drain hose is
sloped downward.
The auxiliary piping can be
connected at the left, rear left,
rear right, right, bottom right or
bottom left as shown below.
Indoor units connectable with a multi-system outdoor unit (Other indoor units are unavailable.)
RAS-B10SKVP-E, RAS-B13SKVP-E, RAS-B16SKVP-E, RAS-M10SKCVP-E, RAS-M13SKCVP-E, RAS-M16SKCVP-E
When using a multi-system outdoor unit, refer to the installation manual provided with the model concerned.
Be sure to install the
indoor unit at a place
where keeps height by
2m or more from the
floor surface.
Extension drain hose
(Option: RB-821SW)
6 mm thick heat resisting
polyethylene foam
For the rear left and left piping
Do not allow the drain hose
to become slack.
Insulate the refrigerant pipes
separately, not together.
When installing the outdoor unit,
leave open in at least two of
directions (A), (B), (C) and (D)
shown in the figure below.
Ensure sufficient space
to allow drainage
Wall
Bottom right
Rear
right
Right
Left
Bottom
left
Rear left
As shown in the figure, position
power cord and connecting cable
downward, and lead out along
piping connection port.
Before installing the wireless remote controller
With the remote controller
cover removed, correctly load
the supplied batteries while
observing their polarity.
3 Batteries
Cover
2 Wireless remote controller
2 Wireless
remote controller
4 Remote controller
holder
7 Remote controller
holder mounting screw
140 mm or more
Hook
Hook
Hook
47 mm or more
74 mm
or more
Z Shield pipe
(for extension
drain hose)
6 Mounting screw
Power cord
Cut the piping hole
slightly sloped
Air filters
5 Plasma pure filter
80 mm or more only
when unobstructed to
the front and both sides
100 mm or more
from wall
200 mm
or more
250 mm or more
from wall
50 mm or more
from wall
In principle,
leave open
10. INSTALLATION PROCEDURE