– 24 –
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
RAS-B10SKVP-E, RAS-B13SKVP-E, RAS-B16SKVP-E
RAS-M10SKCVP-E, RAS-M13SKCVP-E, RAS-M16SKCVP-E
6-2. Outdoor Unit
RAS-3M18SAV-E, RAS-3M18SACV-E
NOTE)
∗
1 : Heat pump model only.
No.
1
2
3
4
5
Parts name
Fan motor (for indoor)
Room temp. sensor (TA-sensor)
Heat exchanger temp. sensor (TC-sensor)
Heat exchanger temp. sensor (TCJ-sensor)
Louver motor
Type
MF-280-30-5R
( – )
( – )
( – )
MP24Z3N
Specifications
DC280–340V, 30W
10k
Ω
at 25°C
10k
Ω
at 25°C
10k
Ω
at 25°C
Output (Rated) 1W, 16 poles, DC12V
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Parts name
SC coil (Noise filter) (L01), (L03)
SC coil (Noise filter) (L02)
DC-DC transformer
Outside fan motor
Relay (4-way valve)
Relay (Power relay)
Discharge temp. sensor
(TD-sensor)
Outside air temp. sensor
(TO-sensor)
Temp. sensor at A room
gas side (TGA-sensor)
Temp. sensor at B room
gas side (TGB-sensor)
Temp. sensor at C room
gas side (TGC-sensor)
Evaporator temp. sensor
(TE-sensor)
Suction temp. sensor
(TS-sensor)
Terminal block (9P)
Fuse
Electrolytic capacitor
Transistor module
Compressor
Compressor thermo.
Diode block (Rectifire)
Reactor (Main)
Reactor (Sub)
Model name
SC-15-06J-B
SC-20-03J
SWT-75
ICF-140-43-2R
G5NB-1A
G4A-1A-PE-CA
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
—
For protection of switching power source (F04)
For protection of power factor converter circuit
breakage
For protection of inverter input overcurrent
For protection of switching power source (F300)
For protection of power source
LLQ2G501KHUATF
6MBI25GS-060-51A
DA130A1F-25F
US622KXTMQO
D25XB60
CH-47-Z-T
CH-43-Z-T
∗
1
∗
1
∗
1
Rating
AC 250V, 15A, 0.6mH
AC 250V, 20A, 0.3mH
Primary side DC 240 – 390V
Secondary side :
7V × 1, 13V × 1
16V × 3
DC 140V, 43W
Coil
: DC 12V
Contact : 2A, AC250V
Coil
: DC 12V
Contact : 20A, AC250V
64k
Ω
(20°C)
10k
Ω
(25°C)
10k
Ω
(25°C)
10k
Ω
(25°C)
10k
Ω
(25°C)
10k
Ω
(25°C)
10k
Ω
(25°C)
AC 250V, 20A
AC 250V, 3.15A
AC 250V, 25A
AC 250V, 25A
AC 250V, 3.15A
AC 250V, 6.3A
DC 400V, 500µF
600V, 25A
3 phases, 4 poles, 1100W
OFF : 125 ± 4°C, ON : 90 ± 5°C
AC 600V, 25A
L = 8mH, 16A
L = 10mH, 1A