3 Tests and Diagnostics
PORTEGE R400 Maintenance Manual (960-623)
[CONFIDENTIAL]
3-25
3.12 Async Test
NOTE
: Async Test is not supported for this model.
To execute the Async Test, select
7
from the DIAGNOSTIC TEST MENU, press
Enter
and
follow the directions displayed on the screen. Move the highlight bar to the subtest you want
to execute and press
Enter
.
Subtest 01 and 02 require the following data format:
Method :
Asynchronous
Speed : 38400BPS
Data
: 8 bits and one parity bit (EVEN)
Data pattern : 20h to 7Eh
Subtest 01
FIR/SIR point to point (send)
NOTE:
To execute subtests 01 and 02, each computer must have access to the other
computer’s infrared port.
This subtest sends 20h through 7Eh data to the receive side, then receives the
sent data and compares it to the original data through the FIR/SIR port.
Subtest 02
FIR/SIR point to point (receive)
This subtest is used with subtest 01 described above. This subtest receives the
data from the send side, then sends the received data through the FIR/SIR
port.
Subtest 03
Wraparound (board)
NOTE:
To execute this subtest, a RS-232C wraparound connector must be connected to
the RS-232C port.
This subtest checks the data send/receive function through the wraparound
connector.
Summary of Contents for Portege R400 Series
Page 10: ...x CONFIDENTIAL PORTÉGÉ R400 Maintenance Manual 960 623 ...
Page 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 12: ...1 ii CONFIDENTIAL PORTEGE R400 Maintenance Manual 960 623 ...
Page 35: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Page 36: ...2 Troubleshooting Procedures 2 ii CONFIDENTIAL PORTEGE R400 Maintenance Manual 960 623 ...
Page 106: ...2 Troubleshooting Procedures 2 68 CONFIDENTIAL PORTEGE R400 Maintenance Manual 960 623 ...
Page 107: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 108: ...3 Tests and Diagnostics 3 ii CONFIDENTIAL PORTEGE R400 Maintenance Manual 960 623 3 ...
Page 112: ...3 Tests and Diagnostics 3 vi CONFIDENTIAL PORTEGE R400 Maintenance Manual 960 623 ...
Page 214: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Page 215: ...4 Replacement Procedures 4 ii CONFIDENTIAL PORTÉGÉ R400 Maintenance Manual 960 623 4 ...
Page 219: ...4 Replacement Procedures 4 vi CONFIDENTIAL PORTÉGÉ R400 Maintenance Manual 960 623 ...
Page 294: ... CONFIDENTIAL Appendices ...
Page 295: ...Appendices App ii CONFIDENTIAL PORTEGE R400 Maintenance Manual 960 623 ...
Page 303: ...Appendices App x CONFIDENTIAL PORTEGE R400 Maintenance Manual 960 623 ...
Page 321: ...Appendices Appendix B Board Layout B 12 CONFIDENTIAL PORTEGE R400 Maintenance Manual 960 623 ...
Page 359: ...Appendices Appendix E Key Layout E 2 CONFIDENTIAL PORTEGE R400 Maintenance Manual 960 623 ...
Page 369: ...Appendices Appendix I Reliability 2 CONFIDENTIAL PORTEGE R4000 Maintenance Manual 960 623 ...