4 Replacement Procedures
4.32 Switch board/Fingerprint sensor board
4-102
[CONFIDENTIAL]
PORTÉGÉ M780 Maintenance Manual (960-809)
Installing the Switch board/Fingerprint sensor board
The following describes the procedure for installing the switch board/fingerprint sensor board.
(See Figure 4-56.)
1.
Connect the
fingerprint sensor cable
to the connector on the back of the fingerprint
sensor board.
2.
Set the
fingerprint sensor board
in place and secure it with the following
screw
.
M2.5
4.0B
FLAT HEAD screw
1
3.
Connect the
switch cable
to the connector on the back of the switch board.
4.
Set the
switch board
in place and secure it with the following
screw
.
M2.5
4.0B
FLAT HEAD screw
1