Troubleshooting Procedures
Procedure 2
Connector Check and Replacement Check
The Digitizer is connected to the system board as below.
Check 1 If any of the connections are loose, reconnect firmly and repeat Procedure 1. If
there is still an error, go to Check 2.
Check 2 The touch screen may be damaged. Replace it with a new one following the
instructions in Chapter 4,
Replacement Procedures
and check the operation. If the
problem still exists, perform Check 3.
Check 3 The web camera/digitizer/fingerprint sensor /sw board cable may be damaged.
Replace it with a new one following the instructions in Chapter 4,
Replacement
Procedures
. If the problem still exists, perform Check 4.
Check 4 The Digitizer may be damaged. Replace it with a new one following the
instructions in Touch screen Troubleshooting and Chapter 4,
Replacement
Procedures
and check the operation. If the problem still exists, perform Check 3.
Check 4 The system board may be damaged. Replace it with a new one following the
instructions in Chapter 4,
Replacement Procedures
.
2-60
[CONFIDENTIAL]
PORTEGE M780 Maintenance Manual (960-809)
Summary of Contents for Portege M780
Page 12: ...1 Hardware Overview 1 2 CONFIDENTIAL PORTEGE M780 Maintenance Manual 960 809 ...
Page 44: ...Troubleshooting Procedures 2 2 CONFIDENTIAL PORTEGE M780 Maintenance Manual 960 809 2 ...
Page 114: ...Tests and Diagnostics 3 2 CONFIDENTIAL PORTEGE M780 Maintenance Manual 960 809 3 ...
Page 304: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Page 305: ...4 Replacement Procedures 4 ii CONFIDENTIAL PORTÉGÉ M780 Maintenance Manual 960 809 4 ...
Page 415: ... CONFIDENTIAL Appendices ...
Page 416: ...Appendices App ii CONFIDENTIAL PORTEGE M780 Maintenance Manual 960 809 ...
Page 484: ...Appendices Appendix I Reliability I 2 CONFIDENTIAL PORTEGE M780 Maintenance Manual 960 809 ...