4 Replacement Procedures
4.28 Touch pad
4.28 Touch pad
Removing the Touch pad
The following describes the procedure for removing the touch pad. (See Figure 4-44 to 4-46.)
1.
Peel off the
glass tapes
.
2.
Disconnect the
relay cable
from the
connector
on the touch pad.
3.
Remove the following
screw
and
touch pad assembly
.
M2.5
4.0B
FLAT HEAD screw
1
M2.5
4.0B FLAT HEAD
Glass tape
Connector
Relay cable
Touch pad assembly
Guide
Glass tape
Figure 4-44 Removing the touch pad (1)
4-70
[CONFIDENTIAL]