4.32 Switch board/Fingerprint sensor board
4 Replacement Procedures
4.32 Switch board/Fingerprint sensor board
Removing the Switch board/Fingerprint sensor board
The following describes the procedure for removing the switch board/fingerprint sensor
board. (See Figure 4-56.)
1.
Remove the following
screw
securing the switch board and pull up the
switch board
.
M2.5
4.0B
FLAT HEAD screw
1
2.
Disconnect the
switch cable
from the connector on the back of the switch board.
3.
Remove the following
screw
securing the fingerprint sensor board and pull up the
fingerprint sensor board
.
M2.5
4.0B
FLAT HEAD screw
1
4.
Disconnect the
fingerprint sensor cable
from the connector on the back of the
fingerprint sensor board.
M2.5x4.0B FLAT HEAD
Fingerprint sensor board
Fingerprint
sensor cable
Switch board
Switch cable
M2.5x4.0B FLAT HEAD
Figure 4-56 Removing the switch board/fingerprint sensor board
PORTÉGÉ M780 Maintenance Manual (960-809)
[CONFIDENTIAL]
4-101
Summary of Contents for Portege M780
Page 12: ...1 Hardware Overview 1 2 CONFIDENTIAL PORTEGE M780 Maintenance Manual 960 809 ...
Page 44: ...Troubleshooting Procedures 2 2 CONFIDENTIAL PORTEGE M780 Maintenance Manual 960 809 2 ...
Page 114: ...Tests and Diagnostics 3 2 CONFIDENTIAL PORTEGE M780 Maintenance Manual 960 809 3 ...
Page 304: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Page 305: ...4 Replacement Procedures 4 ii CONFIDENTIAL PORTÉGÉ M780 Maintenance Manual 960 809 4 ...
Page 415: ... CONFIDENTIAL Appendices ...
Page 416: ...Appendices App ii CONFIDENTIAL PORTEGE M780 Maintenance Manual 960 809 ...
Page 484: ...Appendices Appendix I Reliability I 2 CONFIDENTIAL PORTEGE M780 Maintenance Manual 960 809 ...