12.15 Adjustment of image skew
Assemble the scanning guide and jump plate using the adjustment screw located at the hinge so that the gap
between them is 1.1mm.
Perform copying test. If the image does not satisfy the specification, make finer adjustment by adjustment screw
at right side of hinge.
Note: Loosen the fixing screw to perform the adjustment, and make sure to tighten it when it is finished.
Gap 1.1mm
Platen guide
adjustment screw
fixing screw
Jump plate