13-3
October 2000 © TOSHIBA TEC
MR-3011/3012 SERVICE
13.2 Troubleshooting for Electrical Errors
1)
RADF does not work (except in the case of a jamming is occuring or when the cover is open)
YES
YES
YES
YES
NO
NO
NO
YES
NO
NO
Start
Interface harness
connected properly?
DC+5V supplied
to “B”?
“A”
“B”
“D”
“C”
TP26
TP27
CN1_5pin
TP16
TP30
DC+24V supplied
to “C”?
Empty sensor (“D”)
is 0V when there is paper
exist?
Check or replace the PC board
Check or replace the empty
sensor
Check the PC board and the
copier
Check the fuse and the copier
Connect the harness properly
Check or replace the RADF
open/close switch and jam access
cover switch
DC24V supplied
to “A”?
#Chapter_13.p65
10/11/00, 2:06 PM
3