12.4.5 Feed motor
(1) Remove the harness from the clamp and discon-
nect one connector.
(2) Remove 3 screws and take off the feed motor with
the bracket attached.
(3) Remove the belt and encoder.
Remove 2 screws and take off the feed motor
from the bracket.
Connector
Clamp
Encoder
Belt