EM SERVER DISK DRIVE REPLACEMENT
Power UP Server
Installation Manual August, 2011
16-13
Figure 16-2 EM Server Power Supply Module Replacement
EM SERVER DISK DRIVE
REPLACEMENT
The IP
edge
EM server ships with two Hard Disk Drives (HDD) in a RAID 1
configuration. In the event of a HDD failure the failed drive can be
replaced without data loss or server down-time. The procedure below has
the steps to replace then, rebuild the failed HDD.
1.
Login to Enterprise Manager
2.
In Enterprise Manager select
Application > Webmin
. The Webmin
information screen will appear.
3.
In the Webmin screen select
IPedge > RAID
then, click on the
Status
tab.
4.
Ensure that the
Volume status
is
Enabled
and
Volume state
is
Degraded
.
Important!
If other conditions were displayed, please call Tech-
Support.