EM SERVER POWER SUPPLY REPLACEMENT
Power UP Server
16-12
Installation Manual August, 2011
Power UP Server
1.
Connect the AC Power cords.
2.
Set the rear panel switches to ON.
3.
Wait one minute then, press the front panel Power Switch.
Figure 16-1 EM Server Fan Location
EM SERVER POWER
SUPPLY REPLACEMENT
You do not need to shut down the system to replace an EM server power
supply module. The redundant power supply feature will keep the system
up and running while you replace the failed hot-swap module. Replace
the power supply module with the same model, which can be ordered
from Toshiba.
1.
The failed power supply led will change from green to amber. First
unplug the power cord from the failed power supply module.
2.
To remove the failed power module, push the release tab (on the back
of the power supply) to the side and then pull the module straight out.
Refer to
.
3.
The power supply wiring was designed to detach automatically when
the module is pulled from the chassis.
4.
Replace the failed power module with another PWS-651-1R power
supply module.
5.
Simply push the new power supply module into the power bay until
you hear a click.
6.
Finish by plugging the AC power cord back into the module.
Summary of Contents for IP edge EC
Page 1: ...TOSHIBA Telecommunication Systems Division Installation Manual Title Page August 2011 ...
Page 18: ...This page is intentionally left blank ...
Page 32: ...This page is intentionally left blank ...
Page 78: ...This page is intentionally left blank ...
Page 82: ...This page is intentionally left blank ...
Page 92: ...This page is intentionally left blank ...
Page 96: ...This page is intentionally left blank ...
Page 100: ...This page is intentionally left blank ...
Page 144: ...This page is intentionally left blank ...
Page 205: ...THIS IS THE END OF THE DOCUMENT ...
Page 206: ......