e-STUDIO550/650/810 RADF
16 - 84
JUNE 2002 © TOSHIBA TEC
(5) Remove 1 screw, disconnect 1 connector and
take off the large original exit sensor with the
bracket.
(6) Remove 1 screw and release the large
original exit sensor from the bracket.
(G-11) Read sensor
(1) Remove the ADF left cover.
(2) Remove 1 screw, disconnect 1 connector and
take off the read sensor with the bracket.
(3) Remove 1 screw and release the read sensor
from the bracket.
(G-12) Registration sensor/Original length sensor
(1) Remove the ADF left cover.
(2) Open the jam access cover, remove 5 screws
and take off the upper transport guide.
(3) Release each latch, disconnect each
connector, and take off the registration sensor
and original width sensors.
Large original exit sensor
Read sensor
Upper transport guide
Registration sensor
Original width sensor