JUNE 2002 © TOSHIBA TEC
16 - 35
e-STUDIO550/650/810 RADF
(3) Original jammed not reaching the small original reverse sensor
(from the small original reverse side to the small original exit side)
• Jam detection
This jam is detected during the time after discharging starts at the small original reverse section
until an original reaches the small original reverse sensor.
• Jam timer setting
The setting value for the jam timer is three times as much time as mentioned above.
(4) Original jammed at the small original exit sensor
(from the small original reverse side to the small original exit side)
• Jam detection
This jam is detected during the time after an original reaches the small original exit sensor until it
passes through the small original reverse sensor.
• Jam timer setting
The setting value for the jam timer is 1.5 times as much time as it takes for an LT, which is the
longest original (of all kinds of small-sized paper) when discharging small originals, to pass
through the small original reverse sensor.
16. 6. 5. Jams at small original exit section
(1) Original jammed not reaching the small original exit sensor
(from the intermediate transport section side)
• Jam detection
This jam is detected during the time after an original reaches the intermediate transport roller until
it reaches the small original exit sensor.
• Jam pulse setting
The setting value for the jam pulse is the equivalent number of pulses it takes for an original to
proceed the distance from the intermediate transport roller to the small original exit sensor plus
60mm.
(2) Original jammed at the small original exit sensor (from the intermediate transport section side)
• Jam detection
This jam is detected during the time after the deceleration, which is set to finish at the position
20mm short of the small original exit sensor, starts until an original passes through the small
original exit sensor.
• Jam timer setting
The setting value for the jam timer is the time mentioned above plus necessary time for an original
to proceed 60mm.
Summary of Contents for e-STUDIO 550
Page 2: ...Copyright 2002 TOSHIBA TEC CORPORATION ...
Page 338: ...18 PC BOARDS ...
Page 339: ...JUNE 2002 TOSHIBA TEC 18 1 e STUDIO550 650 810 PC BOARDS 18 PC BOARDS 1 PWA F SYS 340 ...
Page 340: ...e STUDIO550 650 810 PC BOARDS 18 2 JUNE 2002 TOSHIBA TEC 2 PWA F LGC 340 ...
Page 341: ...JUNE 2002 TOSHIBA TEC 18 3 e STUDIO550 650 810 PC BOARDS 3 PWA F SLG 340 ...
Page 342: ...e STUDIO550 650 810 PC BOARDS 18 4 JUNE 2002 TOSHIBA TEC 4 PWA F PLG 340 ...
Page 343: ...JUNE 2002 TOSHIBA TEC 18 5 e STUDIO550 650 810 PC BOARDS 5 PWA F CCD2 340 ...
Page 346: ...1 1 KANDA NISHIKI CHO CHIYODA KU TOKYO 101 8442 JAPAN R02032111900 TTEC ...