e-STUDIO550/650/810 SCANNING SECTION
6 - 18
JUNE 2002 © TOSHIBA TEC
[H] Carriage-1/Carriage-2
(1) Move the carriages toward the exit side.
(2) Remove 2 screws and take off the brackets
fixing the carriage-1 to the wire.
Wire holder jig
Tension spring
(3) Disconnect 1 connector of the lamp power
supply cable and release the cable from 3
clamps.
(4) Move the carriage-1 toward the center (at the
position of the rear and front flame window) and
take off the carriage-1 upward while tilting it.
(5) Attach the wire holder jigs to the wire pulleys
not to uncoil the wire.
(6) Release 2 tension springs.
Carriage-1
Connector
Clamp