(5) Error detection during warming up (2)
If the output voltage of either the center thermistor or side thermistor (rear) does not go over
approx. 1.9V(100°C) even in a certain period of time after it has exceeded 40°C or if it does not
go over approx. 3.2V(150°C) even in a certain period of time after it has exceeded 100°C, the “Call for
service” [C44] is displayed
(6) Error detection during warming up (3)
If the output voltage of the thermistor does not go over approx. 4.0V(200°C) even in a certain period
of time after it has exceeded 150°C, the “Call for service” [C44] is displayed.
(7) Abnormality detection during standby/copying
If the output voltage of either the center thermistor or side thermistor (rear) becames 0.5V or lower
for more than 0.5 sec., the “Call for service” [C43] is displayed, and if that of the side thermistor
(front) becomes 0.5V or lower for more than 0.5 sec., the “Call for service” [C45] is displayed.
(8) Fuser roller thermistor error status counter
• To enhance the safety of the fuser unit, CPU provides the following protection: When the third [C41]
error has occurred after two consecutive [C41] errors, even if an operator turns OFF the power and
back ON, the IH coil is not turned ON and error [C41] is displayed immediately.
However, if the copier becomes ready successfully with the fuser roller thermistor error status counter
“1” or below, the counter is cleared to “0”.
Note: If the heater is not turned ON and either of the error code [C41] to [C45] is still displayed even thougth the
thermistor, thermostat and IH coil have been repaired and the power is turned ON, check the code “400”
in the mode (08) to set the thermistor/heater status counter to “0”.
Reference
* The fuser roller thermistor error status counter does never have values other than 0 ~ 19 entered.
• If the fuser lamp does not turn ON and the “Call for service” [C41] is displayed immediately after
the power is turned ON, check the fuser roller thermistor error status counter. If it is “2” or over,
be sure to check the thermistor, thermostat and IH coil. Reset the counter to “0” (code “400” in
the (08) mode) after repairing them, then turn ON the power.
• If the fuser roller thermistor error status counter is “20” or over (e.g., 21), there is a possibility
that data in BCRAM or BCRAM itself may have been ruined due to causes such as leakage from
the chargers. Check the bias, high-voltage transformers and charge wires to see if any of them
is defective, and also look through all the data in the BCRAM.
쩹
쩸
Summary of Contents for e-STUDIO 550
Page 2: ...Copyright 2002 TOSHIBA TEC CORPORATION ...
Page 338: ...18 PC BOARDS ...
Page 339: ...JUNE 2002 TOSHIBA TEC 18 1 e STUDIO550 650 810 PC BOARDS 18 PC BOARDS 1 PWA F SYS 340 ...
Page 340: ...e STUDIO550 650 810 PC BOARDS 18 2 JUNE 2002 TOSHIBA TEC 2 PWA F LGC 340 ...
Page 341: ...JUNE 2002 TOSHIBA TEC 18 3 e STUDIO550 650 810 PC BOARDS 3 PWA F SLG 340 ...
Page 342: ...e STUDIO550 650 810 PC BOARDS 18 4 JUNE 2002 TOSHIBA TEC 4 PWA F PLG 340 ...
Page 343: ...JUNE 2002 TOSHIBA TEC 18 5 e STUDIO550 650 810 PC BOARDS 5 PWA F CCD2 340 ...
Page 346: ...1 1 KANDA NISHIKI CHO CHIYODA KU TOKYO 101 8442 JAPAN R02032111900 TTEC ...