60 / 92
Copyright © 2016 TOSHIBA TELI CORPORATION, All rights reserved.
http://www.toshiba-teli.co.jp/en/
D4253386C
TimerControl
This section describes TimerControl category for the BU series.
This camera series is able to generate Timer0Active signal, derived from exposure start, by register setting.
This signal can be used as strobe control signal.
TRIG_IN
(Line0)
Exposure
TIMER0 ACTIVE
Delay
Duration
※
ActiveLow
EXPOSURE ACTIVE
Trigger
(Frame Start Trigger)
TriggerDelay
TimerTriggerSource = Line0Active
TimerTriggerSource = ExposureStart
TimerTriggerSource = FrameTrigger
Timer0Active
● Registers
Register
Visibility
Access
Description
TimerSelector
Beginner
R
Returns the selected timer name.
TimerDuration
Beginner
R/W
Sets the width of Timer0Active signal.
TimerDelay
Beginner
R/W
Sets the delay of Timer0Active signal.
TimerTriggerSource
Beginner
R/W
Selects the source of Timer0Active pulse to start.