78 / 92
Copyright © 2016 TOSHIBA TELI CORPORATION, All rights reserved.
http://www.toshiba-teli.co.jp/en/
D4253386C
● Setting
- Select the type of Event notifications
Set the following value to “EventSelector” register. The setting value is Enumeration type.
setting value
Event ID
Timing of Event notification
FrameTrigger (*)
0x8020
Reception of Frame Start Trigger
FrameTriggerError
0x8021
Rejection of Frame Start Trigger
FrameTriggerWait
0x8022
Start of waiting for Frame Start Trigger
FrameTransferStart
0x8030
Start of transferring streaming data
FrameTransferEnd
0x8031
End of transferring streaming data
ExposureStart
0x8040
Start of Exposure
ExposureEnd
0x8041
End of Exposure
Timer0Start
0x9000
Start of Timer0
Timer0End
0x9100
End of Timer0
* initial factory setting
- Set the activation of Event notifications
Set the following value to “EventNotification” register. The setting value is Enumeration type.
setting value
Event notification
Off (*)
Inactive
On
Active
* initial factory setting