59 / 92
Copyright © 2016 TOSHIBA TELI CORPORATION, All rights reserved.
http://www.toshiba-teli.co.jp/en/
D4253386C
Line1 and Line2 are available. Line0 is dedicated input.
UserOutputValueAll
Function
0 (*)
Low level output
1
High level output
* initial factory setting
- Select the polarity of each signal
Set the following value to “LineInverterAll” register. The setting value is Integer type.
Each bit corresponds to each Line. All Lines are settable.Inverter is also inserted to UserOutputValue.
LineInverterAll
Function
0 (*)
non inverted
1
inverted
* initial factory setting
Timer0Active
UserOutput
ExposureActive
FrameTransfer
FrameActive
FrameTriggerWait
Internal Trigger
TimerControl
UserOutputValueAll[2]
Line0
UserOutput
LineSource
LineInverterAll
UserOutputValueAll[1]
LineModeAll
Internal Trigger
(GPIO_Input)
Line2
(GPIO_Input/Output)
Line1
(GPIO_Output)
TriggerSource
GPIO internal circuit diagram
● Note
About the details of Timer0Active signal, refer to “TimerControl” of "Functions".