Care and service
DE
EN
page 49 / 117
ADVICE
If several high-voltage batteries are installed, check each battery individual-
ly on the system screen. At the start of the storage period, the charge state
must be between 30 % and 70 %.
2. Check the
balancing state
.
If the status is not
Balanced
, contact a certified Torqeedo dealer or Torqeedo
Service.
3. Disconnect the system from the AC power supply.
4. Disconnect the 12 V battery from the system.
5. Disconnect the battery terminals.
6. Always store lead and AGM batteries at temperatures above 0 °C.
Regular inspection (every 3 months)
1. For the inspection, connect the 12 V battery.
2. Switch the system on.
3. Check the high-voltage battery state of charge on the system screen.
If several batteries are installed, check each battery individually.
4. Recharge the high-voltage battery if the charge state is less than 20 %.
5. Check whether there are warnings or error messages in the system.
If there is a warning or error message, contact a certified Torqeedo dealer or
Torqeedo Service.
6. Check the
balancing state
.
If the status is not
Balanced
, contact a certified Torqeedo dealer or Torqeedo
Service.
7. Switch the system off.
8. Disconnect the 12 V battery from the system.
Recommissioning the electrical system
1. Connect the 12 V battery to the system.
2. Fully charge the high-voltage battery after every trip.
3. Ensure that all cooling water hoses are securely connected to the on-board in-
take valves.
4. Open the on-board intake valves.
5. For testing, set
Cooling Policy
to
Immediate
on the system display.
6. As soon as the boat is in the water, check the cooling water discharge at the on-
board outlets while the cooling pumps are running.
7. Flush the cooling water circuits with fresh water.
8. Check that pumps work properly and the systems are free from leaks.
9. Set
Cooling Policy
to
Normal
.