84
DE
EN
Installation
5
4
3
2
1
1.
Position the thrust washer (1) on the motor shaft (2).
2.
Position the propeller on the motor shaft, noting the installation direction.
3.
Position the washer (3) on the motor shaft.
NOTE!
Component damage due to thread locking varnish. Do not use locking
varnishes or additives.
4.
Screw the lock nut SW17 (4) onto the motor shaft and tighten it.
•
Lock nut: 11+/- 1 Nm, 97+/-1 in-lbs
5.
Install the galvanic anode (5).
10.4.5 Anti-fouling coating
NOTE!
Observe national regulations on the processing, application, use and
disposal of anti-fouling coatings. Follow the manufacturer's instructions and
processing instructions.
General instructions
To keep your Cruise system free of fouling, you can do the following:
•
Remove the Cruise system from the water after each use and clean it.
•
Regularly clean all components of the Cruise system that are permanently
below the water surface.
•
Use an anti-fouling coating.
Cleaning the components under the water surface
•
Before cleaning work, switch off the Cruise system at the main switch and
secure it against being switched on again by pulling off the switch handle.
•
Do not use tools with sharp edges or abrasive surfaces that may damage
the Cruise system's paintwork.
Using anti-fouling coatings
When using anti-fouling paints, we recommend treating all parts of the
Cruise system that are permanently below the water surface.
1.
Clean the surfaces of the Cruise system that you want to treat.
NOTE!
Do not use abrasives to roughen the surface, otherwise the protective
coating will be damaged.
2.
Thoroughly mask the anodes and, if necessary, the motor shaft.
3.
Observe the processing instructions and the manufacturer's instructions on
personal protective equipment for the respective anti-fouling coating.
Permitted anti-fouling coatings
•
International Trilux 33 in combination with primer Primocon Sperrgrund
•
Hempel Silic One in combination with Hempel Light Primer and Hempel
Silic One Tiecoat
NOTE!
Do not use metal-containing anti-fouling coatings e.g. products
containing copper.
11 Errors and troubleshooting
11.1 Error messages and errors
Display
Cause
Troubleshooting
E02
Stator overtemperature
(motor overheated)
After a short waiting time (approx. 10
minutes), the motor can be operated
slowly. Contact Torqeedo Service.