5.
Install the coring-head cover; refer to
the Coring-Head Cover (page 69)
.
Running the Recall Ground Height
Application
1.
Press the center button on the InfoCenter to
navigate to the R
ECALL
G
ROUND
H
EIGHT
option.
2.
Press the right InfoCenter button to select the
T
EACH
G
ROUND
H
EIGHT
option.
3.
On the Recall Ground Height screen (
), press the center InfoCenter button.
g343406
Figure 113
4.
On the Head Will Lower screen (
),
press the right InfoCenter button.
g343407
Figure 114
Note:
The Lowering Head message displays
and the coring head lowers.
g372402
Figure 115
5.
Watch the outermost tines for the following
out-of-calibration conditions.
•
The tines begin to penetrate the
ground—press the right InfoCenter
button (
) and run the Teach
Ground Height application; refer to
the Teach Ground Height Application (page
36)
.
•
The tines are above the ground—press the
right InfoCenter button and run the Teach
Ground Height application; refer to
the Teach Ground Height Application (page
36)
.
g343408
Figure 116
6.
If the outermost tines lightly touch the ground,
press the right InfoCenter button to raise the
coring head.
Adjusting the Weight
Transfer
The machine transfers weight from the traction unit
to the coring head to help maintain hole depth in
various soil structures. However, if the soil structure
is firm enough to not allow full aeration depth, the
coring head may need additional weight transfer.
The machine is set for normal weight transfer at the
factory. To increase the down pressure of the weight
transfer springs, proceed as follows: