5.6
PROGRAMMING PARAMETERS ON THE K200T-K280T
ENTER
DOWN
Code
Description
Parameters set from digital switch or PC
Presence of electric lock ( without dot=electric lock not present )
Presence of battery ( without dot=battery present)
Partial opening (without dot=disabled =70%, with dot=enabled =40%)
Seal on closure ( without dot=disabled=0; with dot=enabled=Level 2 )
Automatic and partial reclosing time ( without dot=disabled=5 ; with dot=enabled=0 )
Opening speed adjustment at 45cm/s and closure at 25cm/s
Opening/closing speed increase at 45cm/s
Opening speed increase at 65cm/s and closure at 35cm/s
Press and hold <ENTER> for 5 sec to enter the configuration menu.
Press <DOWN> to pass from a parameter to another, press <ENTER> to enable/disable the function.
It is possible to enter the basic parameters using the 7 segment display (detail 11 fig.33 ) and the
<ENTER> and <DOWN> keys.
The presence on the display of a dot next to a parameter code indicates that the function is enabled.
WITHOUT DOT-monitored sensors (with test) type Optex OA-Axist T or
Hotron HR100_CT
WITH DOT-NC not monitored sensors (without test connection)
Safety logic:
53
EN
K200T
-K280T
INSTRUCTIONS FOR INSTALLATION AND USE
Not used
(Allows the use of "Wings free", if the automation board is set up for the "Wings free", function)
Change the operating mode of the buttons for TS1, TS2 and MS1 in ”WINGS FREE”
operation mode ( with dot=enabled ; without dot=disabled )
If the
TS2
remote control is available, pressing the button “Enter only” ,“Wings Free” operation mode is activated.
Pressing the button “Open” for more than 10 seconds, the “Open” operation mode activates.
If the
MS1
program selection knob is available, selecting “Enter only” , “Wings Free” operation mode is activated.
If the
TS1
remote control is available, pressing the button “Open” , “Wings Free” operation mode is activated.
Description of behavior / y parameter = with dot
2. If you have the Topp remote control
TS2
press the smooth side of the first key (open function).
2. Press the “DOWN” key and hold for a further 5 seconds, all remote controls connected to the electronic board will be
deactivated.
To deactivate all radio control devices:
To program the radio control devices (up to 8):
1. Press the “DOWN” key and hold for 5 seconds. The sequence of characters “Radio” appears on the 7-segment
display.
If the Topp
TS1 4-
channel remote control is available, press the second key (Close Function).
To confirm that the remote control has been memorized, the "Radio" character sequence will no longer be displayed.
1. Press the “DOWN” key and hold for 5 seconds, then release it. The sequence of characters “Radio” appears on the 7- segment
display.
To confirm that all programmed remote controls have been deactivated, the sequence of characters "Radio" will no longer be
displayed.