![TOPP K200T Instructions For Installation And Use Manual Download Page 55](http://html.mh-extra.com/html/topp/k200t/k200t_instructions-for-installation-and-use-manual_1129577055.webp)
55
EN
K200T
-K280T
INSTRUCTIONS FOR INSTALLATION AND USE
Warnings are displayed every five seconds for one second.
Every error is reset during the reset/learning stage or by switching off the equipment.
5.8
SELF RESTORE MANAGEMENT OF ERRORS C-D-E-K-N-P-Q
During the zeroing phase (near) the safety sensors are active, and if:
Ÿ
During the slow closing, the employment of safety sensors of the transit space commands a reopening slow.
Ÿ
Additional 2 resets not complete successfully -> automation finally stops in error and you will need the intervention
of a qualified technician.
Ÿ
During the movement, the contemporary employment of at least one safety sensor side and a sensor safety
compartment passage controls the stop of the door.
Ÿ
During the slow opening in the preceding paragraph, the occupation of the side sensors causes a slow reclosing
Ÿ
The 5 attempts are successful -> automation opens and remains stationary in the open for 5 minutes and then
repeated two more attempts to reset at intervals of 5 minutes;
Errors
C-D-K-N-P-Q
cause a momentary arrest of automation, pending the launch of the procedure for restoring
normal operation.
The procedure involves the automatic execution of a reset command (near) and will be carried out as follows:
Ÿ
Zeroing (near) is successful -> automation continues to work properly;
Ÿ
Zeroing (near) fails order -> automation performs a new attempt to reset (near) that is repeated for the number 5
consecutive times;
Battery not installed. Check connector.
Description
Motor prevented by obstacle from opening. Check for obstacles or friction.
Motor prevented by obstacle from closing. Check for obstacles or friction.
S
t
U
V
W
Clock malfunction/not adjust. Set the exact time.
Motor bridge voltage low.
Motor bridge voltage high. The door operates: the LED flashes
Q
r
Inside warning. Check for any short cirtuiti peripherals.
Antipanic alarm actived
Internal safety.
X
Z
R
Motor over-temperature
Display
code 7
Code-error list
( switch)
segments