5.12
DIGITAL PROGRAM SWITCH
This will allow you to scroll the menu upward.
This allows you to increase the value of the function selected
This allows you to confirm the function selected and change mode .
In case of error, if you press this key for 3sec, it will reset to zero
(near).
This allows you to scroll the menu downward. Hold for 4 sec to enter
the menu
TOTAL ENTRY/EXIT
- The external/internal sensors are enabled, the door block is off and the automatic opening of
the door is total.
PARTIAL ENTRY/EXIT
- The external/internal sensors are enabled, the door block is off and the automatic
opening of the door is reduced.
OPEN
- The door opens automatically from whatever position it is in, and remains blocked with the door open.
PHARMACY -
The door has a reduced opening for safe exchange of goods, all sensors are disabled. Requires an
additional electric lost. Opening is activated via remote control or key impulse.
CLOSED
- The door closes automatically from whatever position it is in, all the sensors are disabled and the door
block is on.
ENTER ONLY
- The internal exit sensor is disabled, the external entry sensor is enabled and the door block is on.
EXIT ONLY
- The external entry sensor is disabled, the internal exit sensor is enabled and the door block is on.
LIST OF MODES
The switch with digital keys. model DS2, for surface installation, serves to select different operating modes of
the door using the keys. The program function selected is signaled on the luminous display.
100
14.5
77.5
This allows you to decrease the value of the function selected and
return to the previous menu
Door 1 open -> door 2 does not open as long as the door 1 is open
INTERBLOCK
- You enable the interlock function of a pair of doors (eg. 1/2 and 3/4). The interlock provides the
Combined operation of two doors operated by a single switch that can be set in DS2: single output, single entry and
automatic. Here's an example:
Door 2 opening -> door 1 does not open as long as the door 2 is open.
To enable interlock enter the menu PARAMETERS -> INTERLOCK -> YES.
57
EN
K200T
-K280T
INSTRUCTIONS FOR INSTALLATION AND USE
WINGS FREE -
– The door stops, all sensors and inputs are disabled. The panel locking system disconnects (if any).
Panels are free. The door can be opened or closed manually.
(Allows the use of "Wings free", if the automation board is set up for the "Wings free", function)