PROGATE User manual V-2022-09-20
12 |
E N
3.4
Control with SMS messages
Control the RELAY output with this SMS command:
Activate or deactivate selected output
USER123456
˽021˽N#ST
021= command code
(Activate or deactivate selected output N)
N = output number
ST= output mode:
0
– deactivated output, 1- activated output
E.g. send SMS: USER123456
˽021˽1#1 to activate OUT1.
Output pulse activation for the time interval
USER123456
˽022˽N#TIME#
022= command code,
N = output number 1-32;
TIME = 0-999999 Time interval in seconds for the output activation.
e.g. USER123456
˽022˽2#5# Activate OUT2 for 5 seconds
3.5
Configuration methods
It is possible to configure device in following methods:
1.
SERA2
software via
USB
2.
SERA2
remote
connection
3.
SERANOVA
app
4.
SMS
text messages. For more details, see:
8 SMS Commands for remote control and configuration
SERA2 software via USB
SERA2 software is intended for PROGATE configuration locally via USB port or remotely via 2G/3G/4G network. This software
simplifies system configuration process. SERA2 software is free, which you can download from our website: topkodas.lt
SERA2 remote connection
The system will NOT transmit any data to monitoring station while configuring the system remotely via 2G/3G/4G TLE network
connection. However, during the remote connection session, the data messages are queued up and will be transmitted to the
monitoring station after the configuration session is over.
SMS text messages
In order to configure and control the device by SMS text message, send the text command to the PROGATE SIM card from one of the
listed administrator phone numbers.
System Access codes
Table 5 Default passwords and explanation
Password
Default
How to find and how to change
Explanation
Administrator
password
123456
SERA2> System Options> Access
System administrator password enable to
read/write configuration of the module
Installer code
(for SMS control
and configuration)
000000
SERA2> System Options> Access
This code allows to send SMS commands with
INST identification as well it allows you to enter
programming mode, where you can program all
features, options, and commands of the module
via SERA2 if system administrator is allowed.
SMS User code
(for SMS control
and configuration)
123456
SERA2> System Options> General system options
This code allows to send SMS commands with
USER identification. Note: to control system the
USER phone number must be authorized as well
SIM card PIN
1234
SERA2> GSM Communications> Network/SIM Card
It is automatically ignored if pin request in SIM card
is disabled
App Key
123456
SERA2> GSM Communications> Sera Cloud Service
[APP Key] is used for [SERA Cloud service]
This code is used for remote connection to the
module via cloud service from SERA2 or
SERANOVA app.