PROGATE User manual V-2022-09-20
24 |
E N
Figure 32The example of System Options > General system Options window.
1
Object Name
2
SIM Card PIN
SIM card PIN code. Default 1234
3
Installer Password
The default installer password is
000000
.
This password allows you to enter programming mode, where you can
program all features, options, and commands of the module.
4
SMS User Password
The default SMS User Password is
123456
. This code allows you to utilize arming method, as well as program
user codes.
5
User Access Code
Format
A 4-digit or 6-digit user access code format can be selected.
6
I/O1 Settings
2-Wire Smoke detector (Fire current loop)
or
0-10V Analog Input (Zone or Sensor)
or
Output
or
– 0-20mA, 4-
20mA Current Loop Sensor could be assigned to the I/O1
7
I/O2 Settings
2-Wire Smoke detector (Fire current loop)
or
0-10V Analog Input (Zone or Sensor)
or
Output
or
– 0-20mA, 4-
20mA Current Loop Sensor could be assigned to the I/O2
15
0-10V Analog Input
(Zone or Sensor)
0-10V Analog sensors will be connected to the input
16
Output
Input will be used as output
17
2-Wire Smoke Detector
(Fire current loop)
2-Wire Smoke detectors will be connected t the input.
18
0-10mA, 4-20mA Current
Loop Sensor
0-20mA, 4-20mA Current Loop Sensors will be connected to the input.
8
Clear Event Buffer After
Reset
When the cell is checked, the memory of unsent reports will be deleted after the module resetting
9
Door Chime
When this box is checked, violations of set Delay zones at the alarm turned off will be accompanied by keyboard
audible (Buzzer) signal
10
Bell squawk on ARM/
DISARM
The module can activate the bell output briefly causing the squawk to alert users that the module is being armed,
disarmed or that an Entry or Exit Delay was triggered. Enable or disable the desired option.
11
Auto re-ARM
The module can be programmed to arm the module if there is no activity in the area after the system disarming.
12
Start iButton/RFID
programming
All added iButton keys or RFID cards will be registered in the order of sequence by clicking Start programming
13
STOP iButton/RFID
programming
To finish entering iButton keys or RFID cards, click Stop programming button
19
Test Time
Auto Test report time of day
20
Test Period
Auto Test report period
21
Entry Delay
This delay gives you time to enter the armed premises and enter your code to disarm your system before the
alarm is triggered.
22
Exit Delay
The system will trigger the Exit Delay Timer to provide you with enough time to exit the protected area before the
system is armed.
23
Bell/ Sirel Cut
– off Timer
Duration of audible signal (sirens, Bell) after the alarm system activated. Time shall be written in seconds,
duration from 0 to 9999.
24
Time Zone
25
Daylight saving time
26
Set module time from PC
To set the clock click Set time from PC button and the clock will be set using computer’s clock.
27
Read module time
To read the clock of panel.
28
PC Time
29
Panel Time
14
Reset Device
Reset module command