PROGATE User manual                                                 V-2022-09-20 

 

20  | 

E N

   

SMS

OFF

ON

Remote Control 

Pulse 

 

OFF

ON

Remote Control 

Level

SMS 1

SMS 2

 

OFF

ON

Remote Control 

Pulse 

Dial

 

OFF

ON

Remote Control 

Level

Dial 1

Dial 2

 

System State: 

Output for connection of light indicator of the alarm system 

status.  Within Exit  Delay time  a pulse  signal  is  generated,  and  when  the 
alarm system activated 

– continuous. Signal is terminated by turning off the 

alarm system. 

OFF

ON

System State

Open

Exit Delay

Close

Open

 

AC  OK: 

Output  for  connection  of  indicator  about  control  panel  supply 

from alternating current 

OFF

ON

AC OK

AC OK

AC Lost

AC OK

 

Ready: 

Output for connection of light indicator of input statuses. If all zones 

are clear (none violated), a continuous signal is generated. 

OFF

ON

Ready

Zone Fault

Zone OK

 

Battery OK: 

Output for connection of indicator about control panel supply 

from battery. 

OFF

ON

Battery OK

Battery OK

Battery Lost

Battery OK

 

Alarm  indication: 

Output  for  connection  of  light  indicator  showing  alarm 

status of the alarm system.  After the alarm system actuation a continuous 
signal is generated. 

OFF

ON

Alarm Indication

Open

Close

Open

Alarm

Bell Time

 
 

Lost Primary Channel: 

Output where a continuous signal is generated 

when communication with primary channel was lost. 

OFF

ON

Lost Primary 

Channel

Lost Primary Channel

Restore Primary Channel

 

Fire  Sensor  Reset: 

Output  for  reset  of  fire  sensor  operation.  Its  status 

changes 5 sec. and returns to the initial one. 

OFF

ON

Fire Sensor 

Reset

Fire Sensor Reset

5 seconds

 

Lost  Secondary  Channel: 

Output  where  a  continuous  signal  is 

generated when communication with secondary channel was lost. 

OFF

ON

Lost Secondary 

Channel

Lost Secondary Channel

Restore Primary Channel

 

5.1.3 

Access control output with logging 

If you want to edit existing configuration,  

• 

You have to read it (press “Read” in the command line) 

• 

Edit settings 

• 

Write edited configuration (press “Write” in the command line) 

 

Set output definition to [

Access Gained

] . SERA2>Outputs 

Summary of Contents for PROGATE

Page 1: ...PROGATE Installation Programming Manual Cellular Gate controller PROGATE Multifunctional device access control security home automation This manual includes steps to install set up and use your system...

Page 2: ...customizable The controller is capable of sending event messages to the receiver of a security company PROGATE designed to be easy to use Once installed module can be programmed remotely via GPRS con...

Page 3: ...8 5 1 1 Output PGM wiring Bell Relay Led Wiring 18 5 1 2 Output programming 19 5 1 3 Access control output with logging 20 6 INPUTS 22 6 1 Input zones wiring EOL NO NC 22 7 SERA2 configuration softwar...

Page 4: ...Analog inputs I O1 I O2 0 30V Programmable selectable input or output SMS text for input alarm and restore Burglary alarm zones Input type NC NO EOL EOL TAMPER 5 6K 5 6K Algorithm for zones operation...

Page 5: ...uploaded from the device s memory to the configuration software for further analysis The system logs all information about system configuration system actions and info messages Exit Delay A period of...

Page 6: ...tice Ask the seller before buying Table 2 Additional under request package content Mini USB cable Cellular Antenna 2 5 dBi L Type SMA Connector 4G LTE Antenna 3dBi SMA male Adhesive Mount 2m Cable 4G...

Page 7: ...Contacts Name Optional functions and Description AC DC DC 10 30V AC 12 24V Max 0 2A NC C NO Relay Output 1A 30 V DC 0 5A 125 V AC I O1 I O2 Programmable functions Input with pull up resistor 10K to th...

Page 8: ...controller 3 Flat head 2 5 mm screwdriver 4 External GSM antenna if reception is weak in the area 5 Activated nano SIM card can have turn off PIN code requests 6 Instruction manual for the automatic...

Page 9: ...he gate status can be displayed in SERANOVA More information Quick start PROGATE https www topkodas lt Downloads media Manuals PROGATE_QS_EN pdf Quick start SERANOVA APP https www topkodas lt Download...

Page 10: ...will be able to control gates and other devices remotely as well as administer users view system status and push notifications and view a log of all events 3 3 1 Steps to get started with SERANOVA To...

Page 11: ...in to the system the owner must enter the user s email and user code with which the system will be operated This is the user ID and password This is enter the user email that was used to create the S...

Page 12: ...remote connection session the data messages are queued up and will be transmitted to the monitoring station after the configuration session is over SMS text messages In order to configure and control...

Page 13: ...iguration using SERA2 software With SERA2 software you can change the controller s settings if default settings are not enough Download and Install and open free SERA2 configuration Diagnostic softwar...

Page 14: ...about SMS commands see 8 SMS Commands for remote control and configuration Figure 10System Options General System Options 3 5 4 User codes for access control via keypad and SERANOVA app Each user mus...

Page 15: ...key MASTER The total length of the 1 Wire bus is up to 100 m Depending of cable quality and environment noise iButton probe LED is without resistor External 4 7k 10k resistor required depending of po...

Page 16: ...FID reader Sent the message INST000000 063 0 You will receive the message iButton RFID Caller ID Learning Mode Stopped INST000000 063 S INST Install Configuration of the parameters 000000 Installer s...

Page 17: ...eter Default App Key is 123456 Press Connect Go to SERA2 System Options General system Options Select Dallas 1 Wire Bus for iButton keys Press Write Press Start iButton RFID Caller ID Learning Mode To...

Page 18: ...aling we recommend to use siren DC 12V up to 1500mA It is recommended to connect the siren to the system by using 2 x 0 75 sq mm double insulation cable Auxiliary BUZZER is recommended to be installed...

Page 19: ...time ON to OFF Pulse time Off 3 This cycle will repeat until output is deactivated Output signal Pulse time ON Pulse time OFF Pulse time ON Pulse time OFF Output state Output ON Output OFF Bell Output...

Page 20: ...ery OK Battery Lost Battery OK Alarm indication Output for connection of light indicator showing alarm status of the alarm system After the alarm system actuation a continuous signal is generated OFF...

Page 21: ...Events Log if output will have definition Automation CTRL it also can be controlled by user in any way but it will not generate 421 and 422 events Event log e g 1853 Event 1234 1 401 01 001 Time 2017...

Page 22: ...re sensors DS18b20 or iButton key DS1990A o Aosong 1 Wire bus Humidity Sensor AM2302 DHT22 AM2305 AM2306 6 1 Input zones wiring EOL NO NC The module PROGATE has In1 In2 I O1 I O2 Can be used as inputs...

Page 23: ...ill not be necessary again to set the same parameters If you want to save that is already recorded by the module firstly you must read configuration of the module Press Read 4 icon In order to save co...

Page 24: ...resetting 9 Door Chime When this box is checked violations of set Delay zones at the alarm turned off will be accompanied by keyboard audible Buzzer signal 10 Bell squawk on ARM DISARM The module can...

Page 25: ...module should be set again by auto synchronization or manually System clock can be synchronized in following ways 1 Cloud Server Synchronize by SERA Cloud Service SIM card must have mobile data and S...

Page 26: ...ystem is running on the backup battery and voltage is dropped below allowed value 13 System Voltage Restore The module has detected that the system voltage has been restored 14 Event Delay System low...

Page 27: ...elay zone becomes instant The system will NOT activate siren and keypad buzzer only when Instant Silent zone types is violated Any Delay type zone will operate as Instant type zone when the system is...

Page 28: ...with interruptions will be generated Recommended for smoke fire detectors ON OFF Interior STAY Similar to Instant except the module will auto bypass the zone if Armed in the Stay mode Instant STAY Sim...

Page 29: ...ystem is disturbed When the alarm system is turned off operates like keyboard buzzer 24 Flash Output for connection of light indicator When the alarm system is on a continuous signals generated and if...

Page 30: ...igure 44 Users Access control window 1 ID 2 User Name The name of users who will be able to control the module should be entered in this column 3 User Tel Telephone numbers of users who will be able t...

Page 31: ...ank than the standard Monday Sunday Temporary access that self destructed after a certain time elapses Suppose you must create a Cleaning Crew schedule The schedules are to be set up as follows Monday...

Page 32: ...xt message if programmed containing the violated name The system will send SMS text messages regarding each violated zone separately a If the user phone number is unavailable it will attempt to send t...

Page 33: ...the SMS message 5 Show Zone Number Zone number will be displayed in the SMS message 6 Show Event Time Event time will be displayed in the SMS message 7 Show CID Code Report Contact ID code 8 Zone1 Zo...

Page 34: ...in Custom SMS Text window 7 8 Event Summary Events Event Summary Events The Event Summary Events window illustrates Contact ID codes of the events and enable user to change the text that will be repo...

Page 35: ...e changed after inserting SIM card into any mobile phone 9 System Voltage Power supply voltage Nearby number is value of ADC voltage When multiplying this number by the coefficient Fig 32 voltage valu...

Page 36: ...e entered 10 ARM After pressing the button ARM arm mode should be entered 11 SLEEP After pressing the button SLEEP sleep mode should be entered 12 STAY After pressing the button STAY arm mode should b...

Page 37: ...events System start System arming disarming Zone violated restored Tamper violated restored Zone bypassing Temperature deviation by MIN and MAX boundaries System faults Configuration via USB User pho...

Page 38: ...SERA Cloud Server cloud topkodas lt Standard web browser Firefox Chrome etc Sera Cloud Server opens tunnel between module PROGATE and SERA2 or APP and lets them communicate to each other via TCP proto...

Page 39: ...trol of the module over the Internet ADDR the format of IP address xxx xxx xxx xxx the numbers from 0 to 255 should be separated by dot or domain text length of up to 47 characters PORT TCP port numbe...

Page 40: ...tem configuration control and request for information By default installer code is 000000 which is highly recommended to change User code for SMS commands 6 digit password used for system control and...

Page 41: ...mbers according the user ID number ID user ID number from 1 to 8 INST000000 004 ID TEL OUT OPT NAME e g INST000000 004 1 37066666666 1 10 Jon To enter user s telephone number for remote control via sh...

Page 42: ...ss Gained INST000000 020 N Invert output state 020 command code outputs inversion N output number from 1 to 32 INST000000 021 N ST Output activation or deactivation 021 command code Output activation...

Page 43: ...ssages 092 command code Remote reset of the module via SMS messages INST000000 093 yyyy MM dd HH mm Time of the module setting via SMS message The time is usually synchronized via a server or mobile n...

Page 44: ...N output number 1 10 TIME 0 999999 Time interval in seconds for the output activation USER123456 030 ST Change security system s mode ARM DISARM STAY SLEEP 030 command code Change security system s mo...

Page 45: ...ersion 3 Firmware Configuration software 4 Serial No Module registration number 5 IMEI GSM modem IMEI address Figure 61Explanation of every field in System Info window 9 1 Firmware Update Firmware Thi...

Page 46: ...normal use It does not cover Damage incurred in shipping or handling Damage caused by disaster such as fire flood wind earthquake or lightning Damage due to causes beyond the control of UAB Topkodas...

Page 47: ...dence or building Every fire is different in the amount of smoke produced and the rate of burning Smoke detectors cannot sense all types of fire is equally well Smoke detectors may not provide timely...

Reviews: