Receiver Specifications
P/N 7010-0816
A-11
Digital UHF Receiver Specifications
Table A-6 lists the Digital UHF Receiver’s general specifications.
Environmental Specifications
Table A-7 lists the receiver’s general environmental specifications.
Table A-6. Digital UHF Receiver Specifications
Parameter
Specification
Noise Figure
5 dB
Nominal Input Impedance
50 Ohms
Receiver sensitivity for DBPSK (@ BER
<1x10
-4
, over temperature -30°C to
+60°C)
-116 dBm
Dynamic Range
-119 to -34 dBm
Max. Input Signal Level
-10 dBm
Co-channel Rejection
-12 dB
Adjacent Channel Selectivity
-60 dB
Spurious Radiations
< 2 nW
Table A-7. HiPer Ga/Gb Environmental Specifications
Parameter
Specification
Temperature
Operation:
-30°C to +60°C
Storage:
-40°C to +85°C
Humidity
Min 5 cycles / 1 cycle=48h
Max 600C, max RH95% operating
Max 650C, RH% (none operating)
Altitude
-1000m under sea level or 8500m above
sea level