17
(c)V-reset mode (Under internal-sync / Consecutive HD IN)
Exposure starts at the timing of TRIG signal IN. After each exposure is completed, the camera
outputs video immediately by resetting VD. (HD is not reset)
(1/100s 2:1 Interlace)
(1/50s Non-interlace)
Irrespective of TRIG IN phase, the camera always outputs ODD field image.
l
Correct output signal does not come out from VIDEO 2 OUT.
VIDEO OUT1
Exposure time
(e-shutter-speed or
pulse width)
CCD
Exposure
TRIG IN
(Positive)
Automatically returns to normal shutter
if H level stays for 10V (1/5s) or longer
Random trigger shutter
Normal shutter
Normal shutter
TRIG IN not acceptable
for 1V after mode change
Indefinite
VD, V-sync pause during standby
WEN OUT
VD, V-sync output
for 1V only
VIDEO OUT1
CCD
Exposure
TRIG IN
WEN OUT
Automatically returns to normal shutter
if H level stays for 10V (1/5s) or longer
TRIG IN not acceptable for
1V after mode change
Random trigger shutter
Normal shutter
Normal shutter
VD, V-SYNC output
for 1V only
Exposure time
(DIP-SW or pulse width)
Indefinite
EVEN
Image B
EVEN
Image A
ODD
ODD
Image C
ODD
ODD
ODD
Image D
ODD
Indefinite
EVEN
Image B
ODD
Image A
EVEN
ODD
Image C
EVEN
ODD
ODD
Image D
EVEN
VIDEO OUT2
VD, V-SYNC pause during standby