(9-5-4) Partial-scan sync-signal reset OPTION
RTS Non-reset / V-reset selection can be made via camera rear-panel DIP SW. The selection is
also available under 1/2 and 1/4 partial scan operation.
(a)Non-reset OPTION
VD signal interval: 312.5H (1/100s 2:1 Interlace mode) / 625H (1/50s non-interlace mode)
Readout speed: Normal scan speed readout
(b)V reset (E-shutter disabled) OPTION
The VD gets reset immediately after readout.
(b-1)Under 1/2 partial-scan
VD signal interval: 156.5H (1/100s 2:1 Interlace mode) / 312H (1/50s non-interlace mode),
Readout speed: Twice (x2) normal scan speed readout
(b-2) Under 1/4 partial-scan
VD signal interval 78.5H (1/100s 2:1 Interlace mode) / 156H (1/50s non-interlace mode),
Readout speed: Quadruple (x4) normal scan speed readout
l
The function/features noted as “option” or shown with the OPTION mark in this document is
available as optional function/feature (= Production on order) and not provided as standard
function. Please contact our sales staff for details.
l
Under standard version, partial-scan function is not available. (Normal mode only)
VIDEO OUT
Partial
image A
Partial
image B
Partial
image C
312.5H
625H
VIDEO OUT
Partial
image A
Partial
image B
Partial
image C
Partial
image E
Partial
image D
156.5H 312H
VIDEO OUT
Partial
image A
Partial
image B
Partial
image C
Partial
image E
Partial
image D
78.5H/156H