35
[Sync signal spec]
WEN readout timing pulse
Output signal WEN
Output signal level More than 4V(p-p), Emitter follower output
Polarity Positive
Pulse width 1H output (See timing chart)
[Partial scan spec]
(Option)
Input signal level LOW: 0 ~ 0.5V
HIGH: 4 ~ 5V
Input impedance High impedance (10k-ohm)
Operation mode (a)1/2 partial-scan
(b)1/4 partial-scan
(c)Programmable partial-scan (rear-panel DIP SW selection)
No
Scan mode
Sync
Reset
E-shutter
Normal
E-shutter
RTS
1
Non-reset
Enabled
2
V-reset
Disabled
3
Consecutive
HD VD IN
Non-reset
Enabled
4
Consecutive
HD IN
V-reset
Disabled
5
Programmable
partial-scan
Consecutive
HD VD IN
Non-reset
Enabled
Enabled
Internal
1/2 partial-scan
1/4 partial-scan
*The function/features noted as “option” or shown with the OPTION mark in this
document is available as optional function/feature (= Production on order) and not
provided as standard function. Please contact our sales staff for details.
**Under standard version, partial-scan function is not available. (Normal mode only)
[Mechanical spec]
External dimension 44(W) x 29(H) x 88(D)mm (Not including protrusion)
Refer to the attached ex-view drawing
Weight Approximately 140g
Lens mount C mount (Conforms to EIAJ TT4506)
GND / insulation Circuit GND ~ Chassis electrically conducted
[Ambient condition]
Performance guaranteed:
Temperature: From 0 through 40 degree C
Humidity: From 30 through 90 percent (No condensing)
Operation guaranteed:
Temperature: From -5 through 45 degree C
Humidity: From 10 through 90 percent (No condensing)
Storage:
Temperature: From -20 through 60 degree C
Humidity: From 10 through 90 percent (No condensing)
EMI Conforms to EN50081-2