34
2-8-3
SIDE MOUNT SILENCED BRACKET (TNB-7J, 151LU2 )
1.
Place the breaker in a horizontal position,
and lay it down on wooden blocks
Stop the excavator engine.
2.
Remove the hex cap bolts (9) with the
hex wrench(#14 ㎜).
Remove the retainer cover plate (8) and
take the retainer isolators (7) out.
3.
M8 thread hole is available on the retainer
pin (4) and pull the retainer pins using the
retainer pin puller bolt (B) or push it out
with the chisel pin puller (A) to take them
out.
4.
Remove the chisel (5) from the chisel
holder.
Use a crane (C) when removing the chisel
(5).
Pay attention the gravity position and watch
out not pinch fingers in the process.
4
A
B
WARNING
C
5
9
8
7
4
B
Summary of Contents for TNB-08M