33
2-8-2
SIDE MOUNT SILENCED BRACKET (TNB-2M, 3MB, 4M, 6M )
1.
Place the breaker in a horizontal position,
and lay it down on wooden blocks.
Stop the excavator engine.
2.
Remove the hex cap bolts (9) with hex
wrench.
Remove the retainer cover plate (8) and
take the retainer isolator (7) out.
3.
Remove the retainer pins (4) up from
bottom using the chisel pin remover (A).
4.
Remove the chisel (5) from the chisel
holder.
Use a crane (C) when handle the chisel(5)
of TNB-6M.
Watch out not to pinch fingers.
Wear the protection glass, safety shoes and
glove as protection gear.
4
A
WARNING
C
5
9
7
8