52
12.
Use canvas sheet (D) to cover the breaker.
Lower the chisel side to avoid the rain
water penetration into the chisel holder.
D
After a long period of storage, replace the gas when using the breaker again.
In regard to the recharge of the nitrogen gas refer to the chapter of “INSPECTION OF
NITROGEN GAS PRESSURE AND RECHARGE”.
CAUTION
8
6
9
9
8
○
×
To avoid drop of retainer pin stopper plug(9),
make sure to clean the retainer pin stopper
plug(9) and its hole, and insert the retainer
stopper plug(9) using hammer deep into its
position so that surface of that plug (9) get
lower than the breaker body.
CAUTION
CAUTION
Failure to keep the above storage manner, it may cause to rust inside the breaker or
malfunction at early stage.
Operate the breaker with rusty components may cause seal damage or seizure.
CAUTION
When using a breaker stored for 1 month or more, the piston and the cylinder may not
have the oil film.
Please make sure to operate the breaker according to the section "Test run".
Summary of Contents for TNB-08M
Page 133: ...TOKU Pneumatic Co Ltd...