Using a Remote Unit
59
TAB PCR_PID <#>
where # is a valid PIDs
0
Sets the PCR PID to be included in the output transport stream. Zero
is the default PID.
Front panel command equivalent: none
TAB PMT_PID <#>
where # is a valid PIDs
0
Sets the Program Map Table (PMT) PID to be included in the output
transport stream. Zero is the default PID.
Front panel command equivalent: none
TAB PROGNUM
DVB = 1-231
ATSC = 2-231
If DVB = 1
If ATSC = 2
Controls the program number for the PAT. Changing the PAT program
number automatically sets the PMT to the same program number and
sets the EIT and SDT service ID to match the program number.
Front panel command equivalent: Config>Service>Setup>Service ID
TAB PROVIDER
<string>
Unnamed
Used to enter the service provider name; name can be up to 115
characters in length.
Front panel command equivalent: Config>Service>Setup>Provider
TAB SATFREQ ###.#####
000.00000 to
999.99999
011.75725
Sets the satellite frequency in GHz.
Front panel command equivalent: none
TAB SATPOS ###.#
000.0 to 999.9
019.2°
Sets the satellite orbital position in degrees.
Front panel command equivalent: none
TAB SDT_NAME
<string>
If DVB =
service 1
If ATSC = ch2
User to enter the service name; name can be up to 115 characters in
length.
Front panel command equivalent: Config>Service>Setup>Name
TAB TSID
0 to 65535
1
Sets the transport stream ID for the PAT. Changing the PAT Transport
Stream ID automatically changes the EIT, NIT, SDT Transport Stream
IDs to the same ID.
Front panel command equivalent: none
TAB TYPE
None, MPEG, DVB,
ATSC
DVB
Controls the type of PSI/SI tables to be provided. Works in conjunction
with the CM Load Def command.
Front panel command equivalent: Config>Tx Strm>Table Type
TAB USR_A_PID <#>
where # is a valid PIDs
0
Sets the Data A PID to be included in the output transport stream.
Zero is the default PID.
Front panel command equivalent: none
TAB USR_B_PID <#>
where # is a valid PIDs
0
Sets the Data B PID to be included in the output transport stream.
Zero is the default PID.
Front panel command equivalent: none
TAB VID_PID <#>
where # is a valid PIDs
0
Sets the video PID to be included in the output transport stream. Zero
is the default PID.
Front panel command equivalent: none
TCA ADD <string>
where string is the
alpha-numeric label in
the format
name@MAC address
—
Adds a decoder to the conditional access database. The string can be
up to 90 alphanumeric characters in length and must include a name,
the @ sign, and the decoder’s MAC address in the format name@mac
address. The string cannot contain any spaces.
To determine the decoder’s MAC address, refer to the appropriate
Tiernan user guide which accompanied that product.
Note: Non-Tiernan IRDs cannot be added to the decoder database.
Front panel command equivalent: Config>CA>IRD Cfg>New
TCA AUTH <label>
where label is the
alpha-numeric string
specified in the
TCA Add command
—
Authorizes a Tiernan decoder to receive broadcast signals.
Note: Non-Tiernan IRDs cannot be authorized.
Front panel command equivalent: Config>CA>IRD Cfg>List
TCA CLR
—
—
Clears the active subscriber list.
Front panel command equivalent: none
TE3000 Remote Command Descriptions
(continued)
Remote Command
Parameter Range
Factory
Default
Description
Summary of Contents for TE3000
Page 10: ...viii Preface ...
Page 14: ...4 TE3000 Overview ...
Page 52: ...42 Using the Front Panel ...
Page 94: ...84 Maintenance and Software Upgrades ...
Page 96: ...86 Technical Specifications ...
Page 102: ...92 TE3000 PID Assignments ...
Page 112: ...102 Glossary ...