Using a Remote Unit
51
AXD.<slot>.<port> DR
1200 to 4096000 bps
1024000 bps
Sets the number of data bits for the synchronous auxiliary data
channel.
Note: The data rate for the auxiliary data channel reduces the total
transport stream bit rate available for the video signal; therefore, an
auxiliary data rate should be selected that meets but does not exceed
the site-specific operational requirements.
AXD DR is only available when AXD Mode is set to sync.
Front panel command equivalent: Config>Service>Data>Data Rate
AXD.<slot>.<port> EN
Off, On
Off
Enables or disables the auxiliary data channel in the transport stream.
Parameters are:
!
Off = auxiliary data is not included in the transport stream
!
On = auxiliary data is included in the transport stream.
Front panel command equivalent: Config>Service>Data>Enable
AXD.<slot>.<port> IF
RS232, RS422
RS232
Sets the auxiliary data electrical interface. Parameters are:
!
When AXD Mode is set to async, AXDIF options are RS-232
(default) and RS-422.
!
When AXD Mode is set to sync, this command is query-only and
displays the synchronous interface RS-422
Front panel command equivalent: Config>Service>Data>Interface
AXD.<slot>.<port> MODE
Async, Sync
Async
Sets the data communication mode; parameters are: async = sets the
data communication mode to asynchronous; syn c= sets the data
communication mode to synchronous. The following commands can
be issued when AXD Mode is set to:
!
Async: AXD IF, AXD BAUD, AXD DATA, AXD PARITY, AXD STOP
!
Sync: AXD IF, AXD DR, AXD SRC
Front panel command equivalent: Config>Service>Data>Comm Mode
AXD.<slot>.<port> PARITY
N, O, E
N
Sets the parity bit for asynchronous serial communication. Parameters
are: N = none, O = odd, E = even.
Front panel command equivalent: Config>Service>Data>Parity
AXD.<slot>.<port> SRC
INT, EXT
INT
Sets the clock source for the synchronous auxiliary data channel;
parameters are:
!
INT = internal, uses ST to latch the data
!
EXT = external, uses TT to latch the data
AXD SRC is only available when AXD Mode is set to sync.
Front panel command equivalent: Config>Service>Data>Clock Source
AXD.<slot>.<port> STOP
1, 2
1
Sets the number of stop bits for the asynchronous serial protocol.
Front panel command equivalent: Config>Service>Data>Stop Bits
CM CREATE <string>
where string specifies
a user-defined label
Creates a user-defined label under which a configuration set may be
saved. The <string> parameter must be an alpha-numeric label of not
more than 15 characters. The string must begin with an alphabetic
character. Up to 100 user configurations may be saved and recalled.
Front panel command equivalent: Config>Presets>New
CM DELETE <string>
where string specifies
a user-defined label
—
Deletes the specified user-defined configuration.
Front panel command equivalent: Config>Presets>Delete
CM LIST
—
—
Query-only; displays a list of all current configuration labels.
Front panel command equivalent: none
CM RENAME <old label>: <new label>
where <old label>
specifies the current
user-defined label and
<new label> defines
the new label name
—
Renames an existing label.
Front panel command equivalent: Config>Presets>Rename
TE3000 Remote Command Descriptions
(continued)
Remote Command
Parameter Range
Factory
Default
Description
Summary of Contents for TE3000
Page 10: ...viii Preface ...
Page 14: ...4 TE3000 Overview ...
Page 52: ...42 Using the Front Panel ...
Page 94: ...84 Maintenance and Software Upgrades ...
Page 96: ...86 Technical Specifications ...
Page 102: ...92 TE3000 PID Assignments ...
Page 112: ...102 Glossary ...