System Installation
System Installation
System Installation
System Installation
TT-3616A Interconnection Box (optional)
TT-3616A Interconnection Box (optional)
TT-3616A Interconnection Box (optional)
TT-3616A Interconnection Box (optional)
Page
Page
Page
Page 3-30
3-30
3-30
3-30
25Jul00
25Jul00
25Jul00
25Jul00
3.5
TT-3616A Interconnection Box
(optional)
F1
TT-3616A
Interconnection Box
X5
X6
Term/Open
X1
X2
X3
AUX1
AUX2
AUX3
AUX4
GND
GND
GND
GND
2A mT
TT-3606C
Transceiver
ARCNET
ARCNET
(X6)
X4
9-32V DC
Figure 20 TT-3616A Interconnection Box.
The Interconnection Box distributes the different I/O signals from
TT-3606C to separate connectors for easy and quick connection.
The AUX connectors, connected to X4, is split into 4 different fe-
male parts with screw terminals for mounting.
Each end of the ARCNET has to be terminated. If the TT-3616A is
located at the end of the ARCNET, switch (X6) has to be set to
“Term”.
In Figure 21 is shown different configurations of the TT-3616A
where it is possible to add +5V and GND to X5, X6, and inverting
the polarity of ARCNET. Left setting is factory.