background image

825B073G

PTU15

 

Mechanical installation

PTU15

Compact ultrasonic level transmitter

To reach a good and safe measurement, avoiding spurious echo
(not reflected from the surface to measure) need to take care about
the sensor sensibility volume in the sound path, no obstacles or
objects must be present into the sensibility volume (lobe), see fig.2/
D/E.
On fig.2 some suggestion:
1)  Install perpendiculary at  the surface, see fig.2/A
2)  Don’t use with foaming products, see fig.2/B
3)  Avoid installation where the product distance could be less

than 0,7m, see fig.2/C

4)  No obstacles or objects must be present into the sensibility

volume, see fig.2/D/E

applied solutions for the applications

TECHNICAL DATA

Enclosure material:

PP

Mechanical installation:

1” BSP

on request with PP DN150 PN6 flange screwed

Mechanical protection:

IP68

Electrical connection:

n.1 output cables  (L=3m) or

IP68 male connector with linking cable

Working temperature:                                         

 -25 ÷ +75°C

Pressure:

                                from 0,5 to 1,5bar (absolute)

Power  supply:

24Vdc

Power consumption:

                                                           1W

Analog output:

                         4÷20mA max load 750 ohm

Serial port:

RS485

Max measure range:

 

    0,7÷12m

[The above distance must be intended from perfect
reflecting surfaces, in contrary case decreases the
maximum measurable distance]
Temperature compensation:        

PT100 from -30 to +80°C

Accuracy:

    not better than +/-2mm

Resolution:

1mm

Calibration:

two push-buttons, for self-acquisition

or by SWING unit

Warm-up:

   30 minutes  normally

LEDs display:

red LED for supply

                    yellow LED flashing for echo receiving

PTU15

 

Overall dimensions

fig.2

A)

B)

C)

D)

E)

fig.3

fig.4

Summary of Contents for PTU15

Page 1: ...applications TECHNICAL DATA Enclosure material PP Mechanical installation 1 BSP on request with PP DN150 PN6 flange screwed Mechanical protection IP68 Electrical connection n 1 output cables L 3m or IP68 male connector with linking cable Working temperature 25 75 C Pressure from 0 5 to 1 5bar absolute Power supply 24Vdc Power consumption 1W Analog output 4 20mA max load 750 ohm Serial port RS485 M...

Page 2: ... connected to the negative output current A special J box with P1 and P2 calibration push buttons built in is available on request The picture below shows the connectors and the push buttons for the 4 20mA version calibration Available a RS485 serial port to communicate to PC or PLC On request the SoniSoft S W communication for PC and the RS485 RS232 conversion module are available Analog output v...

Page 3: ...han press simultaneously P1 and P2 release them and verify that led will stay fix lightened Press two times P1 release it and wait until led is flashing again before move the sensor The distance has been memorised and associated to 4mA output To calibrate 20mA needs to put the PTU15 at the distance at which you want 20mA output Wait till the led is flashing than press simultaneously P1 and P2 rele...

Page 4: ...ade in conformity to the SGM LEKTRA procedu re Quality Control Manager Production and ceck date documentation subject to technical change with no prior warning 5 1 U T P e d o C n o i s r e V A m 3 e l b a c g n i k n i l h t i w 5 8 4 S R t i n u g n i w S o t d e t c e n n o c e b o t d e n g i s e D B m 3 e l b a c g n i k n i l h t i w r e t t i m s n a r t t u p t u o 5 8 4 S R A m 0 2 4 C m ...

Reviews: